Contact
en
de fr

M-Bus Gateway TCP/IP

CMe3100

C Me3100v2 001 freigestellt

Product categories

Water,
Heat / Cooling,
Electricity,
Gas

M-Bus Metering Gateway

Water

Drinking Water

Heat / Cooling

Electricity

Gas

System technology

Wired

M-Bus,

Modbus,

Ethernet

Instruments

Smart City

Smart Building

Your benefits

  • Intelligent link between system and M-Bus devices:
    The CMe3100 M-Bus metering gateway fulfils all requirements in terms of flexibility and versatility and makes data integration easier than ever before.
  • Flexible meter reading:
    Reading of the measured values by the time-saving online query via the web platform or on site.
  • Unique capabilities:
    Whereas previously it was difficult to connect an M-Bus system via Modbus TCP, JSON-RPC or REST, the CMe3100 enables integration into peripheral systems, e.g. a building management system, without additional devices.
  • Preferred M-Bus splitter:
    The CMe3100 supports the complete M-Bus standard, and splitting all bus participants to two further systems via wired M-Bus is easy.
  • Infrared interface for modular extensions:
    Metering gateway can be used for the connection of additional measuring points (––> investment protection).

Applications

  • Fast and simple measurement data acquisition incl. integrated statistical functions
  • Integration of measurement data in (building) management systems or other peripheral systems
  • Complete gateway integration based on e.g. DLMS or REST
C Me3100v2 001 freigestellt

Properties

  • Data can be sent to FTP and https server
  • Different executions with support for 8, 32, 64, 128, 256 or 512 devices available
  • Various templates available for sending meter data
  • Integration of wireless M-Bus participants (T & C mode) with CMi-Box
  • DIN mounted, modular and expandable – future-proof solution
  • Various extension modules (infrared interface) available
  • Supports static and dynamic IP addressing
  • Configuration changes and ad hoc read-out can be carried out remotely
  • M-Bus protocol according to EN 13757-3
  • Two M-Bus slave outputs for splitting the system to further systems
  • Flexible extension system TCP, JSON-RPC, DLMS/REST

Product information

Integration M-Bus Gateway
Scada Kopie

Fig. 1: Measurement data acquisition and integration in SCADA system

Gatewayint Kopie

Fig. 2: Gateway integration via DLMS / REST server

Technical Data
CMe3100 CMeX10
Mechanics CMe3100 CMeX10 CMeX11 CMeX12S CMeX13S
Dimensions (HxBxD) 90x70x64 mm (4 DIN modules) 90x36x65 mm (2 DIN modules) 90x108x65 mm (6 DIN modules)
Weight 190 g approx. 100 g approx. 220 g
Installation Hat rail (EN 50022), 35 mm Hat rail (EN 50022), 35 mm
Casing material Polyamide Polyamide
Protection class IP20 IP20
CMe3100 CMeX10
Terminals CMe3100 CMeX10 CMeX11 CMeX12S CMeX13S
Power supply L, N Screw terminal cable 0 - 2.5 mm2 0.5 Nm tightening torque L, N L, N Screw terminal cable 0.75 - 2.5 mm2 0.5 Nm tightening torque L, N, Erde Screw terminal cable 0,75 - 2,5 mm2 0,5 Nm tightening torque
M-Bus Screw terminal, 0,25 - 1.5 mm2 Pin terminal solid wire Ø 0.6 - 0.8 mm Pin terminal solid wire Ø 0.6 - 0.8 mm and Screw terminal cable 0.25 - 2.5 mm2 0.5 Nm tightening torque
Ethernet RJ45 Not available
RS232 Not available Not available RJ45
USB Typ A (Master Port) / Typ mini B (Slave Port) Not available
CMe3100 CMeX10
Electrical CMe3100 CMeX10 CMeX11 CMeX12S CMeX13S
Nominal Voltage 100…240 V AC / ± 10% / (50/60 Hz) 100…240 V AC / ± 10% / (50/60 Hz)
Power consumption (max.) <15 W <3 W <25 W
Power consumption (nom.) <5 W M-Bus loads x 0,07 W + 1.5 W
Installation category CAT 3 CAT 2
CMe3100 CMeX10
Ethernet-Specifications CMe3100 CMeX10 CMeX11 CMeX12S CMeX13S
Velocity Auto 10/100 MBit not avaiable
Duplex half/full Duplex not avaiable
Configuration Web-Browser not avaiable
CMe3100 CMeX10
M-Bus-Specifications CMe3100 CMeX10 CMeX11 CMeX12S CMeX13S
M-Bus standard EN 13757 EN 13757
M-Bus baud rate 300, 2400 Bit/s 300, 2400 Bit/s
Maximum connected M-Bus loads (each 1.5 mA) 32 (modularly expandable up to 1056) 32 64 128 256
Maximum cable length 1000 m1) 1000 m1)
Max load capacitance 100 nF/km, max. 90 ohm 100 nF/km, max. 90 ohm
Bus voltage (nom.) 28 V DC 28 V DC 42 V DC
IR interface for extension modules Yes Yes
Extension possibilities (Additional M-Bus loads) 32, 64, 128, 256 Yes Maximum of 5 CMe modules side by side
CMe3100 CMeX10
Ambient conditions CMe3100 CMeX10 CMeX11 CMeX12S CMeX13S
Temperatur Betrieb -25 bis +55 °C -30 bis +55 °C
Temperatur Lagerung -40 bis +85 °C -40 bis +85 °C
Luftfeuchtigkeit 5% - 90% (nicht kondensierend) 5% - 90% (nicht kondensierend)
Montageort Indoor (optional mit IP67 Gehäuse für Outdoor) Indoor (optional mit IP67 Gehäuse für Outdoor)
CMe3100 CMeX10
Approvals CMe3100 CMeX10 CMeX11 CMeX12S CMeX13S
EMC EN 61000-6-2, EN 61000-6-3, FCC 47 CFR
Safety EN 62368-1 2018, UL 62368-1:2014 Ed.2], CSA C22.2 62368-1:2014 Ed.2]

1) The maximum possible network reach (entire cable length) as well as the distance to the M-Bus end devices depends greatly on the network topology, the number of connected devices, the cross-section of the used cables and the transfer rate.

Enquire

Last updated: 14.03.2025
Back to the selection