Contact
en

Heat and cooling meter

Integral-V UltraMaxx (CAN)

Integral V Ultra Ma XX 100mm Photo Room png Photo Room

Product categories

Heat / Cooling

Combined ultrasonic heat and cooling meter DN 15, 20

Heat / Cooling

Ultrasonic

Wired

Impulse,

M-Bus

Wireless

wM-Bus

Smart Building

Your benefits

  • Ultrasonic technology:
    Long-term stable energy measurement with maximum measuring accuracy
  • Compact design:
    Less installation space required
  • Large measuring range:
    Lower storage costs
  • Replaceable calculator:
    Flexible mounting possible (compact/split)
  • Display of operating faults and soiling warning:
    Increased operational safety
  • Big display:
    Easy to read

Applications

  • High-end device for building management
  • As a replacement for mechanical impeller heat meters
  • Metering of heat and/or cooling consumption in building management

Options

  • Execution on-site reading (Supply via battery, small calculator housing)
  • Execution with 2 pulse outputs for heating- and cooling energy (Supply via battery, small calculator housing)
  • Execution with M-Bus interface and 4 water meter inputs (Supply via battery, large calculator housing)
  • Execution with M-Bus interface and 2 water meter inputs (Supply via M-Bus, large calculator housing)
Integral V Ultra Ma XX 100mm Photo Room png Photo Room

Properties

  • Nominal diameters DN 15 or DN 20
  • Nominal flow rates qp 1,5 or qp 2,5
  • Supply via 10-year battery or M-Bus with back-up battery
  • Max. operating pressure PN 16 bar
  • Universal installation position
  • No moving parts
  • Electronic calculator
  • LCD-resolution 8 digits
  • Temperature range 0 – 90 °C
  • Temperature sensor Pt 500
  • 18 month register
  • Max. values (P, Q, T)
  • Standard EN 1434
  • Conformity according European Measuring Instruments Directive (MID) or Conformity according to the Directive Measurement Canada

Product information

Technical Data
Header
Temperature range 0 to 90 °C
Temperature difference 3 to 90 K
LCD resolution 99‘999‘999 kWh 999‘999,99 m3
Battery lifetime (Execution with battery) 10 years
Battery lifetime back-up battery (Execution supply via M-Bus) 1 year
Environment class EN 1434 - class C, 2004/22/EC class E1, M1
Protection class IP54
Environment temperature +5 to +55 °C
Storage temperature -10 to +60 °C
Optical interface EN 60870-5 / M-Bus protocol
Temperature sensor type 2-wires, Pt 500
Cable length 0,5 m
Temperature sensor Direct immersion sensor Pocket sensor
Sensor element Pt 500 Pt 500
Resistor acc. to EN 60751 / EN 1434 EN 60751 / EN 1434
Measuring tolerance Class B Class B
Temperature measuring range 0 to 90 °C 0 to 90 °C
Temperature difference 3 to 90 K 3 to 90 K
Sensor diameter 3,6/5,4 mm 6 mm
Sensor length 27,5 mm 50 mm
Connection thread M10x1 Knurled nut M12
Cable type Smooth cable Coiled cable
Cable length 1,75 m 1,2 m
Volume measuring meter
Nominal diameter DN mm 15 15 20
Operating pressure PN bar 16 16 16
Connection thread on meter G…A Inch ¾ 1 1
Nominal flow rate qp m3/h 1,5 1,5 2,5
Maximum flow rate qs m3/h 3 3 5
Minimum flow rate qi l/h 6 6 10
Starting flow l/h 2 2 4
Kvs value m3/h 3 3 5
Temperature max. °C 90 90 90
Measuring range qi/qp 1:250 1:250 1:250
Metrological class EN 1434 - class 2 EN 1434 - class 2 EN 1434 - class 2
Protection class IP67 IP67 IP67
Dimensions
Length without couplings A mm 110 130 130
Height total B mm 128 128 128
Height from pipe centre line C mm 86 86 86
Width calculator D mm 88 88 88
Height calculator (small housing) E mm 86 86 86
Height calculator (large housing) F mm 126 126 126
Dimension Diagram
Intergral V Ultra Ma XX E Pe20316 2ennn
Installation

Integral-V UltraMaXX is approved for all horizontal and vertical installation positions, even overhead.

In combination with the flexible calculation unit attachment, it ensures an optimum reading position.

Integral Vs Ultra Ma XX E Pd20317 3 Einbaulagen
Flow Measuring Dynamic

The exceptionally large measuring dynamic (2-3300 l/h at qp 1,5) means Integral-V UltraMaXX is a real multi-range meter

Intergral V Ultra Ma XX E Pe20316 3enii
Typical Head Loss Curve
Intergral V Ultra Ma XX E Pe20316 3enen
Options

Integral-V UltraMaXX is supplied with integrated options. This enables quick and efficient installation and system setup.

The following versions are available.

Specification for M-Bus interface
Protocol M-Bus according EN 13757-3
M-Bus standard load Supply via battery: 1 standard load (1,5 mA) Supply via M-Bus: 2 standard loads (3 mA)
Standard baud rate 2400 baud
Standard data set Manufacturer no., energy, volume, flow, power, temperatures (supply, return, difference), operating time, date and time, optional volume water meter inputs, firmware version, software version
Specification for water meter inputs
Pulse value 1, 2,5, 10, 25, 100, 250 l/pulse (programmable, same pulse value for all connected water meters, standard 10 l)
Scanning voltage Typically 3 V
Impulse recognition Contact closed: R <500 Ω Contact opened: R > 1 MΩ Impulse duration / break every > 3 s
Cable length max. 10 m
Specification for pulse outputs for heating- and cooling energy
Pulse value Heating energy: 1 pulse = 1 kWh Cooling energy: 1 pulse = 1 kWh
Pulse characteristic Passive transducer, Open Collector Pull-down switch
Scanning voltage max. 30 V, min. 2,5 V
Max. permissible current max. 20 mA
Max. internal resistance Ron 100 Ω (during pulse ON)
Impulse length 120 ms
Multi-function display

Reading errors are minimised by the concise layout on 3 display levels and the clear symbols for status and alarm messages. The various display levels are selected via a red button. Press the button for app. 3 s to access the next level.

Intergral V Ultra Ma XX E Pe20316 4enenen

Enquire

Last updated: 06.08.2025
Back to the selection