Contact
en

Heat and cooling meter

Integral-V UltraMaxx (USA)

Integral V Ultra Ma XX 100mm Photo Room png Photo Room

Product categories

Heat / Cooling

Combined ultrasonic heat and cooling meter ½" and ¾"

Heat / Cooling

Ultrasonic

Wired

Impulse,

M-Bus

Wireless

wM-Bus

Smart Building

Your benefits

  • Ultrasonic technology:
    Long-term stable energy measurement with maximum measuring accuracy
  • Compact design:
    Less installation space required
  • Large measuring range:
    Lower storage costs
  • Replaceable calculator:
    Flexible mounting possible (compact/split)
  • Display of operating faults and soiling warning:
    Increased operational safety
  • Big display:
    Easy to read

Applications

  • High-end device for building management
  • As a replacement for mechanical impeller heat meters
  • Metering of heat and/or cooling consumption in building management

Options

  • Execution on-site reading (Supply via battery, small calculator housing)
  • Execution with 2 pulse outputs for heating- and cooling energy (Supply via battery, small calculator housing)
  • Execution with M-Bus interface and 4 water meter inputs (Supply via battery, large calculator housing)
  • Execution with M-Bus interface and 2 water meter inputs (Supply via M-Bus, large calculator housing)
Integral V Ultra Ma XX 100mm Photo Room png Photo Room

Properties

  • Nominal diameters NPS ½ or 3/4 inch
  • Nominal flow rates qp 6.6 gpm or qp 11 gpm
  • Supply via 10-year battery or M-Bus with back-up battery
  • Max. operating pressure PN 230 psi
  • Universal installation position
  • No moving parts
  • Electronic calculator
  • LCD-resolution 8 digits
  • Temperature range 32 - 194 °F
  • Temperature sensor Pt 500
  • 18 month register
  • Max. values (P, Q, T)
  • Standard EN 1434
  • Conformity according European Measuring Instruments Directive (MID) or Conformity according to the Directive Measurement Canada

Product information

Technical Data
Calculator
Temperature range 32 to 194 °F
Temperature difference 3 to 90 K
LCD resolution 99‘999‘999 kWh 999‘999,99 m3
Battery lifetime (Execution with battery) 10 years
Battery lifetime back-up battery (Execution supply via M-Bus) 1 year
Environment class EN 1434 - class C, 2004/22/EC class E1, M1
Protection class IP54
Environment temperature 41 to 131 °F
Storage temperature 14 to 140 °F
Optical interface EN 60870-5 / M-Bus protocol
Temperature sensor type 2-wires, Pt 500
Cable length 19.7 in
Temperature sensor Direct immersion sensor Pocket sensor
Sensor element Pt 500 Pt 500
Resistor acc. to EN 60751 / EN 1434 EN 60751 / EN 1434
Measuring tolerance Class B Class B
Temperature measuring range 32 to 194 °F 32 to 194 °F
Temperature difference 3 to 90 K 3 to 90 K
Sensor diameter 0.142/0.213 in 0.236 in
Sensor length 1.083 in 1.969 in
Connection thread M10x1 Knurled nut M12
Cable type Smooth cable Coiled cable
Cable length 5 ft 9 in 3 ft 11 in
Volume measuring meter
Nominal diameter NPS inch 1/2 1/2 3/4
Operating pressure PN psi 232 232 232
Connection thread on meter G…A Inch ¾ 1 1
Nominal flow rate qp gpm 6.6 6.6 11
Maximum flow rate qs gpm 13.2 13.2 22
Minimum flow rate qi gpm 0.026 0.026 0.044
Starting flow gpm 0.009 0.009 0.018
Kvs value gpm 13.21 13.21 22.01
Temperature max. °F 194 194 194
Measuring range qi/qp 1:250 1:250 1:250
Metrological class EN 1434 - class 2 EN 1434 - class 2 EN 1434 - class 2
Protection class IP67 IP67 IP67
Dimensions
Length without couplings A inch 4.33 5.12 5.12
Height total B inch 5.04 5.04 5.04
Height from pipe centre line C inch 3.39 3.39 3.39
Width calculator D inch 3.46 3.46 3.46
Height calculator (small housing) E inch 3.39 3.39 3.39
Height calculator (large housing) F inch 4.96 4.96 4.96
Dimension Diagram
EP20316 dimensions imperial
Installation

Integral-V UltraMaXX is approved for all horizontal and vertical installation positions, even overhead.

In combination with the flexible calculation unit attachment, it ensures an optimum reading position.

Integral Vs Ultra Ma XX E Pd20317 3 Einbaulagen
Flow Measuring Dynamic

The exceptionally large measuring dynamic (0.009–14.53 gpm at qp 6.6 gpm) means Integral-V UltraMaXX is a real multi-range meter

Intergral V Ultra Ma XX E Pe20316 imperial
Typical Head Loss Curve
EP20316 loss curve imperial
Options

Integral-V UltraMaXX is supplied with integrated options. This enables quick and efficient installation and system setup.

The following versions are available.

Specification for pulse outputs for heating- and cooling energy
Pulse value Heating energy: 1 pulse = 1 kWh Cooling energy: 1 pulse = 1 kWh
Pulse characteristic Passive transducer, Open Collector Pull-down switch
Scanning voltage max. 30 V, min. 2.5 V
Max. permissible current max. 20 mA
Max. internal resistance Ron 100 Ω (during pulse ON)
Impulse length 120 ms
Specification for water meter inputs
Pulse value 1, 2.5, 10, 25, 100, 250 l/pulse (programmable, same pulse value for all connected water meters, standard 10 l)
Scanning voltage Typically 3 V
Impulse recognition Contact closed: R <500 Ω Contact opened: R > 1 MΩ Impulse duration / break every > 3 s
Cable length max. 393.7 in
Specification for M-Bus interface
Protocol M-Bus according EN 13757-3
M-Bus standard load Supply via battery: 1 standard load (1.5 mA) Supply via M-Bus: 2 standard loads (3 mA)
Standard baud rate 2400 baud
Standard data set Manufacturer no., energy, volume, flow, power, temperatures (supply, return, difference), operating time, date and time, optional volume water meter inputs, firmware version, software version
Multi-function display

Reading errors are minimised by the concise layout on 3 display levels and the clear symbols for status and alarm messages. The various display levels are selected via a red button. Press the button for app. 3 s to access the next level.

Intergral V Ultra Ma XX E Pe20316 4enenen

Enquire

Last updated: 06.08.2025
Back to the selection