Contact
en
de fr

For fully filled pipes

KATflow 230

Grossdurchflussmessung Wasserversorgung KA Tflow230

Product categories

Water

Mobile Clamp-On ultrasonic flow meter

Water

Hydropower

Ultrasonic

Smart Infrastructure

Your benefits

  • Pipe diameter range 10 mm to 3000 mm
  • Temperature range for sensors -30 °C to +250 °C (-22 °F to +482 °F)
  • Selectable three-line LCD display and full keypad
  • Robust IP 65 aluminium enclosure
  • Battery life up to 24 hours with easily replaceable battery cartridge
  • Measurement of two flows simultaneously

Applications

  • Heating, Ventilation and Air Conditioning (HVAC) measurements
  • Large pipe measurement with two sensor pairs in ‘X’ configuration
  • Temporary replacement of conventional in-line flowmeters
  • Building surveys on large facilities
  • Efficiency monitoring of heat exchangers

Options

  • Optional pipe wall thickness gauge
  • Available with crush-proof IP 67 transport case or lightweight soft case
  • Expansion box for additional input or output configuration and special solutions
  • Software for data evaluation
  • Special waterproof solution available for harsh environmental conditions
Grossdurchflussmessung Wasserversorgung KA Tflow230

Properties

  • Dual flow monitoring with sum, average, difference and maximum calculations
  • PT100 inputs for heat quantity (thermal energy) measurement
  • Process output options including current, open-collector, relay
  • Large data logger and software for sampling and data transfer
  • Stainless steel sensors, cable and connectors as standard

Product information

Flowmeter
Performance

Measurement principle Ultrasonic transit-time difference
Flow velocity range 0,01 ... 25 m/s
Resolution 0,25 mm/s
Repeatability 0.15 % of measured value, ±0.015 m/s
Accuracy Volume flow: ±1 ... 3 % of measured value depending on application ±0.5 % of measured value with process calibration Flow velocity (mean): ±0.5 % of measured value
Turn down ratio 1/100 (equivalent to 0.25 ... 25 m/s)
Measurement rate 100 Hz (standard)
Response time 1 s
Damping of displayed value 0 ... 99 s (selectable by user)
Gaseous and solid content of liquid media <10 % of volume
E Pd60109 01

KATflow 230 (dimensions in mm)

General

Enclosure type Portable
Degree of protection IP 65 according to EN 60529
Operating temperature -10 ... +60 °C (+14 ... +140 °F)
Housing material Extruded aluminium, AI MG Si 0.5, lids die-cast zinc alloy GD-Zn AL 4 CU 1
Measurement channels 1 or 2
Calculation functions Average, difference, sum, maximum (dual-channel use only)
Power supply Internal rechargeable batteries: 8 x NiMH AA 2850 mAh Power adapter: 100 ... 240 V AC input, 9 V DC output External battery pack: 12 V 105 Ah, 25 kg (optional)
Operating time Up to 24 h with fully charged internal batteries
Display LCD graphic display, 128 x 64 dots, backlit
Dimensions 266 (H) x 168 (B) x 37 (T) mm
Weight Approx. 2.0 kg
Power consumption <5 W
Operating languages English, French, German, Dutch, Spanish, Italian, Russian, Czech, Turkish, Romanian (others on request)
Communication

Type RS 232, USB cable (optional)
Transmitted data Measured and totalised value, parameter set and configuration, logged data
E Pd60109 02

KATflow 230 in crush-proof IP 67 transport case

E Pd60109 03

KATflow 230 in operation

 

 

Internal data logger

Storage capacity Approx. 30,000 measurements (each comprising up to 10 selectable measurement units), logger size 5 MB Approx. 100,000 measurements (each comprising up to 10 selectable measurement units), logger size 16 MB (on request)
Logged data All measured and totalised values, parameter sets
Software KATdata+

Functionality Download of measured values/parameter sets, graphical presentation, list format, export to third party software, online transfer of measured data
Operating systems Windows 10, 8, 7, Vista, XP, NT, 2000; Linux
Quantity and units of measurement

Volumetric flow rate m3/h, m3/min, m3 /s, l/h, l/min, l/s USgal/h (US gallons per hour), USgal/min, USgal/s bbl/d (barrels per day), bbl/h, bbl/min
Flow velocity m/s, ft/s, inch/s
Mass flow rate g/s, t/h, kg/h, kg/min
Volume m3, l, gal (US gallons), bbl
Mass g, kg, t
Heat flow W, kW, MW (with heat quantity measurement option)
Heat quantity J, kJ, kW/h (with heat quantity measurement option)
Temperature °C (with heat quantity measurement option)
Process inputs (galvanically isolated)

Temperature PT100 (Clamp-On sensors), three- or four-wire circuit, measurement range: -30 ... +250 °C (-22 ... +482 °F), resolution: 0.1 K, accuracy: ±0.2 K (two or four inputs available)
Process outputs (galvanically isolated)

Current 0/4 ... 20 mA active (RLoad <500 Ω), 16 bit resolution, U = 30 V, accuracy: 0.1 %
Digital open-collector Value: 0.01 ... 1000/unit, width: 1 ... 990 ms, U = 24 V, I max = 4 mA
Digital relay Form A SPST (NO), U = 48 V, I max = 250 mA

Further process outputs available on application.

Transducers
K1L, K1N, K1E

Pipe diameter range 50 ... 3000 mm
Dimensions of sensor heads 60 (h) x 30 (w) x 34 (d) mm
Material of sensor heads Stainless steel
Material of cable conduits Type K1L: PVC Type K1N/E: Stainless steel
Temperature range Type K1L: -30 ... +80 °C (-22 ... +176 °F) Type K1N: -30 ... +130 °C (-22 ... +266 °F) Type K1E: -30 ... +250 °C (-22 ... +482 °F) (for short periods up to +300 °C (+572°F))
Degree of protection IP 66 according to EN 60529 (IP 67 and IP 68 on request)
Standard cable lengths Type K1L: 5.0 m Type K1N/E: 4.0 m
E Pd60109 04

K1N/E transducers

E Pd60109 05

K1L transducers

E Pd60109 06

K1N/E transducers with ODU/LEMO connector

K4L, K4N, K4E

Pipe diameter range 10 ... 250 mm for type K4N/E 10 ... 250 mm for type K4L
Dimensions of sensor heads 43 (h) x 18 (w) x 22 (d) mm
Material of sensor heads Stainless steel
Material of cable conduits Type K4L: PVC Type K4N/E: Stainless steel
Temperature range Type K4L: -30 ... +80 °C (-22 ... +176 °F) Type K4N: -30 ... +130 °C (-22 ... +266 °F) Type K4E: -30 ... +250 °C (-22 ... +482 °F) (for short periods up to +300 °C (+572°F))
Degree of protection IP 66 according to EN 60529 (IP 67 and IP 68 on request)
Standard cable lengths Type K4L: 5.0 m Type K4N/E: 2.5 m
E Pd60109 07

K4N/E transducers

E Pd60109 08

K4L transducers

E Pd60109 09

K4N/E transducers with ODU/LEMO connector

Transducer mounting accessories
General

Diameter range and mounting types Clamping set (metal strap with screw), stainless steel: DN 10 ... 40 Clips and chains, chain length 1 m, stainless steel: DN 15 ... 310 Clips and chains, chain length 2 m, stainless steel: DN 25 ... 600 Clips and chains, chain length 4 m (2 x 2 m), stainless steel: DN 25 ... 1,200
E Pd60109 10

Mounting clip and chains for use with portable flowmeter

E Pd60109 11

Mounting clip

E Pd60109 12

Transducers mounted using chains and clips

General

Diameter range and mounting types Mounting fixture, rail and magnets (for type K4 ): DN 10 ... 250 Mounting fixture, rail and magnets (for type K1 ): DN 50 ... 3000
Mounting fixture for flexible hoses Custom made mounting bracket, stainless steel (available on request)
E Pd60109 13

Mounting fixture, rail and magnets

E Pd60109 14

Mounting fixture, rail and magnets

E Pd60109 15

Example of mounting fixture for flexible hoses

PT100 Clamp-On sensors
General

Type PT100 (Clamp-On sensors)
Measurement range -30 ... +250 °C (-22 ... +482 °F)
Circuits 4-wire
Accuracy T ±(0.15 °C + 2 x 10 -3 x T [°C]), class A
Accuracy ∆T ≤ 0,1 K (3 K <∆T <6 K) corresponding to EN 1434-1
Response time 50 s
Dimensions of sensor heads 20 (h) x 15 (w) x 15 (d) mm
Material of sensor heads Aluminium
Material of cable jacket PTFE
Cable length 3,0 m
E Pd60109 16

PT100 transducer

E Pd60109 17

PT100 transducer fixed to pipe

E Pd60109 18

KATflow 230 with PT100 transducer

 

Wall thickness gauges (optional)
Wall thickness gauge NT

Temperature range -20 ... +100 °C (-4 ... +212 °F)
Measuring range 1.0 ... 200 mm
Resolution 0.01 mm
Linearity 0.1 mm
Cable length 1.5 m
Wall thickness gauge HT

Temperature range 0 ... +500 °C (+32 ... +932 °F)
Measuring range 1.0 ... 200 mm
Resolution 0.01 mm
Linearity 0.1 mm
Cable length 1.5 m
E Pd60109 19

Wall thickness gauge NT

E Pd60109 20

Wall thickness gauge NT in use

E Pd60109 21

Wall thickness gauge HT in use

Transport accessories
Crush-proof transport case

Dimensions (external) 190 (h) x 480 (w) x 385 (d) mm
Weight (empty) 3.71 kg
Degree of protection IP 67 according to EN 60529
Outside material Polypropylene/resin compound
Inside material High-density polyurethane foam
Soft transport case

Dimensions (external) 175 (h) x 450 (w) x 320 (d) mm
Weight (empty) 750 g
Degree of protection No IP rating
Outside material Nylon
Inside material Nylon
E Pd60109 22

Crush-proof IP 67 transport case

E Pd60109 23

KATflow 230 soft transport case

Enquire

Last updated: 21.03.2025
Back to the selection