Contact

M-Bus data logger

M-Bus Center (Discontinued)

EMU mbus gwf

Product categories

M-Bus data logger for automatic readout of up to 250 loads and continuous data acquisition for energy management according to ISO 50001

Smart City

Smart Building

Your benefits

  • Integrated M-Bus level converter for 20 / 60 / 120 / 250 M-Bus loads
  • Web compatible, remote readout via Web browser
  • Ad-hoc analysis and validation
  • Professional data processing
  • Visualisation of consumption makes energy consumption transparent
  • Firmware update and backup via Web interface
  • System connection via OPC UA and BACnet IP

Applications

  • Fast and simple measurement data acquisition, incl. integrated statistical functions
  • Integration of measurement data in (building) management systems or other peripheral systems
  • Suitable for heat, water, gas and electric meters with M-Bus
  • Performance monitoring and energy management
EMU mbus gwf

Properties

  • M-Bus data logger for a max. of 250 loads
  • Data logging on micro SD card
  • Integrated M-Bus level converter/master
  • Supports all M-Bus devices according to EN 13757-2, -3
  • Automatic search for M-Bus devices
  • Visualisation of consumption per day / week / month
  • Backlit LCD display 60x30 mm
  • Compact design: Dimensions (LxWxD) 90x90x67 mm (5 TE)
  • Integrated website via IP address
  • Load profile for all energy values
  • Data export in CSV file and FTP upload of measured values
  • Multi-user compatible
  • Firmware update via TCP/IP
  • System connection via OPC UA and BACnet IP
  • Conformity (MID)

Product information

System components for BACnet integration
Systemanbindung
Technical data
Mechanics
Dimensions (HxWxD) 90 x 90 x 67 (5 DIN modules)
Weight Approx. 400 g
Mounting DIN rail (DIN 50022), 35 mm
Housing material Polycarbonate, recyclable, non-combustible
Protection class IP 20
Terminals
Interfaces 1 x USB type A 1 x USB type B 1 x Ethernet 10/100 base RJ45
Inputs 3 x M-Bus 4 x S0 pulse input 2 x temperature PT1000
System connection BACnet IP and OPC UA
Outputs 2 x relay
Operating voltage 24 V DC
Current consumption Max. 1 A
Product information
Number of M-Bus slaves Max. 20 / 60 / 120 / 250 (per 1.5 mA)
Evaluation Web server / Diagram suitable for ISO 50001
M-Bus level converter Integrated high performance level converter
Data export .csv and JSON file, other formats available upon request
System connection Via BACnet IP and OPC UA
Data memory Micro SD card
Firmware update Yes, possible via user interface
Backup Yes, possible via user interface
Configuration Local and remote configuration with Web server
Product information
Temperature range 0-55 °C
M-Bus baud rate 300, 600, 1200, 2400, 4800, 9600
M-Bus quiescent current Max. 375 mA (250 x 1.5 mA)
Compatibility Heat, water, gas and electric meters with M-Bus according to EN 13757-2, -3
Electrical isolation, short-circuit and overload protection Yes
Safety CE Mark
EMC measurement EN 61000-6-2
Interference immunity EN 61000-6-3
M-Bus standard EN 13757-2,-3
Energy management Suitable for ISO 50001
BACnet IP B-ASC zertifiziert
Display Backlit LCD display
Weight Approx. 400 g
Mounting 35 mm DIN rail
Housing Polycarbonate, recyclable, non-combustible

Enquire

Last updated: 30.07.2025
Back to the selection