Contact
en
de fr

GWFcoder® -Interface

M-Bus / M-Bus / M-Bus

Thumbnail

Product categories

Water,
Heat / Cooling,
Gas

Remote meter reading

Water

Drinking Water

Heat / Cooling

Gas

System technology

Smart City

Your benefits

  • Interface splitter:
    Multiple utilisation of meter data
  • Supply voltage via M-Bus:
    No additional mains adapter required
  • Clearly marked connection terminals:
    Easy on-site installation

Applications

  • With this interface two different management systems in a building can read out an M-Bus meter for energy optimisation simultaneously and independently
  • Using the interface, previously installed M-Bus meters (GWFcoder® from version 5.0 and higher) can be connected to an additional management system of the building services engineering or the tenant
Thumbnail

Properties

  • Meter reading via the primary or secondary address 1)
  • Various possible parameter settings for baud rates
  • One M-Bus/M-Bus – M-Bus interface is required for each GWFcoder®meter
  • DIN rail or wall mounted
  • With this interface one M-Bus meter can be integrated into two independent M-Bus networks simultaneously and read out separately. The interface automatically reads out the connected M-Bus meter at specified intervals and saves the current data set in the internal memory. If a readout occurs, the data is immediately available and transferred to the building management systems.

Product information

Components
Mbus3
Technical Data
Data transfer M-Bus
Baud rate M-Bus OUT 1 2400 baud (default) or 300 baud
Baud rate M-Bus OUT 2 2400 baud (default) or 300 baud
Primary address M-Bus 1–250
Secondary address1) Meter number (eight digits)
M-Bus unit load
M-Bus OUT 1 1 M-Bus unit load (1,5 mA - supply)
M-Bus OUT 2 4 M-Bus unit loads (6 mA - supply)
Connectable meters
1 meter with max. 2 M-Bus unit loads (3 mA)
Installation
The interface can be installed at the M-Bus master or the meter.
Max. cable length
M-Bus connection cable Network-dependent
Dimensions and weight
Dimensions 75x55x110 mm
Weight app. 100 g
Application area
Temperature 0 to +50 °C
Protection class IP40
Interfaces
M-Bus according to EN 13757 (supports REQ_UD2, SND_NKE)
Type of mounting
DIN rail or wall mounted
Connection and signal transfer/Interface
M-Bus OUT 1 M-Bus master according to EN 13757 building management system After «Power On», the interface requires app. 2 minutes before it is ready for operation.
M-Bus OUT 2 M-Bus master according to EN 13757 building management system After «Power On», the interface requires app. 2 minutes before it is ready for operation.
M-Bus IN M-Bus meter Meter reading possible via the primary or secondary address1)

1) Firmware version 2B and higher

Interface M Bus M Bus M Bus E Pd40228 2

Enquire

Last updated: 20.02.2025
Back to the selection