Calculator

Multical® 803

Multical 803 Fernwaerme Zaehler Rechenwerk front

Product categories

Heat / Cooling

Calculator

Heat / Cooling

Ultrasonic

System technology

Wired

Impulse,

M-Bus,

Modbus,

BacNET

Wireless

wM-Bus,

LoRaWAN

Smart City

Smart Building

Your benefits

  • Ultrasonic technology:
    Long-term stable energy measurement with maximum measurement accuracy
  • Large illuminated display:
    Easy to read
  • Built-in 24 V DC auxiliary power supply
    No external transformer installation required
  • Auto Detect function:
    Automatically detects ULTRAFLOW® and sensor type
  • Comprehensive data logger:
    Instant access to information for analysis and optimization purposes
  • Option cards for various functions:
    - Affordable base unit
    - Additional functions can be added later
  • CH refrigeration certification (METAS) incl. initial calibration:
    Approved for use in commercial transactions

Applications

  • Energy measurements for district heating supplies
  • Heat and/or cooling consumption measurement in building services engineering
  • Arithmetic unit for local or remote reading
  • Leakage and pipe burst monitoring in district heating systems

Options

  • Mixed fluid version (803-M) available on request
  • Option cards for
    - M-Bus / 2 water meter inputs
    - M-Bus / 2 pulse outputs energy + volume
    - Radio OMS T1, 868 MHz
    - 2 active analog outputs 0/4…20 mA (mains power supply required)
    - LonWorks, TP/FT-10 / 2 water meter inputs (high-power power supply required)
    - BACnet MS/TP (RS485) + 2 water meter inputs (mains power supply required)
    - Modbus RTU (RS485) + 2 water meter inputs (mains power supply required)
    - Modbus TCP-IP / 2 water meter inputs (high-power power supply required)
    - BACnet IP + 2 water meter inputs (high-power power supply required)
    - LoRaWAN int./ext. antenna
Multical 803 Fernwaerme Zaehler Rechenwerk front

Properties

  • Electronic calculator
  • LCD display, resolution 7 or 8 digits, with backlighting
  • Non-volatile EEPROM memory
  • 4 module slots for option cards
  • 6 years battery backup
  • Pt 500 temperature sensor, 2-/4-wire technology
  • Standard EN 1434
  • Mains supply 230 V AC
  • IP65 protection
  • Impulsions de sortie énergie + volume
  • Can be combined with the following volume measuring elements: ULTRAFLOW®, impeller meter with reed pulse generator and magnetic-inductive meter
  • Type testing/approval: Heat: Conformity with European Measuring Instruments Directive (MID) / Cold: CH approval (METAS) incl. initial calibration

Product information

Technical data
Performance data for the MULTICAL® 803 calculator
Temperature measurement range 2 to 180 °C
Temperature difference measuring range 3 to 170 K
Temperature resolution on display 0,01 °C
LCD resolution 7 or 8 digits with a digit height of 10 mm
Resolution of the display 0‘000,0001 / 00‘000,001 / 000‘000,01 / 0‘000‘001,0 (in kWh/MWh)
Energy display unit MWh
Display unit Power m3
Display unit Volume l/h
Display unit Flow rate kWh
Standardprogrammierung GWF für Impulswertigkeit von Volumenmessteil mit Reed-Impulsgeber 1 pulse = 2,5 liters
Protection class IP65
Environmental class A and C according to EN 1434
Ambient temperature +5 to +55 °C (non-condensing)
Storage temperature -20 to +60 °C
Display unit for consumption meters 1+2 m3
Weight approx. 1.15 kg
Power supply
Power supply 230 V AC +15/-30%, 50/60 Hz
Power consumption 7 W for powering 4 communication modules
Battery backup 1) 3.65 V DC, 2 x AA lithium battery
Backup period Up to 6 years (without maintenance), replaceable
Replacement interval 10 years under normal operating conditions
Data logger (EEPROM) 1400 hours, 460 days, 36 months, 20 years, 280 info codes (last 50 can be read on display) à l'écran)
Clock / Calendar Clock, calendar, leap year compensation, key date

1) The use of data modules, frequent data communication, and high ambient temperatures reduce battery life.

Flow measurement ULTRAFLOW® Reed switch 24 V active pulses
EN 1434 Impulse class IC IB IA
Pulse input 680 kΩ Pullup jusqu'à 3,6 V 680 kΩ Pullup jusqu'à 3,6 V 120 mA à 24 V
Pulse ON 0,4 V en 1 ms ‹ 0,4 V en › 300 ms <4 V pour > 3 ms
Pulse OFF 2,5 V en 4 ms › 2,5 V en › 100 ms > 12 V pour > 4 ms
Pulse frequency ‹128 Hz ‹ 1 Hz ‹128 Hz
Electrical insulation Non Non 2 kV
Maximum cable length 10 m 10 m 100 m
Temperature sensor Pt 500, 4-wire technology / glycol = Pt 500, 2-wire technology
Technical data Option cards
Pulse inputs water meter
Pulse input 680 kΩ Pullup jusqu'à 3,6 V
Pulse ON ‹ 0,4 V pour › 500 ms
Pulse OFF › 2,5 V pour › 500 ms
Frequency ‹ 1 Hz
Electrical insulation Non
Maximum cable length 25 m
Pulse outputs
Pulse output type Opto FET
External voltage 1… 48 V DC/V AC
Current <50 mA
Residual voltage RON ≤ 40 Ω
Electrical insulation 2 kV
Maximum cable length 25 m
Dimension diagram
MULTICAL 803 Rechenwerk E Pd80115 1 3 Massbilder

Enquire

Last updated: 23.02.2026