sonico® NANO Wired M-Bus Module
NMB-1
Product categories
Water
sonico® NANO Wired M-Bus Module
Water
Drinking Water
System technology
Wired
M-Bus
Software
Infin.io,
GWF Life
Smart City
Smart Building
Your benefits
- Wired M-Bus module for tool-free retrofitting of an already installed or new sonico® NANO
Quick and easy installation on site - Pairing between NMB-1 and sonico® NANO takes place automatically via the radio interface
Tap & Go commissioning with GWFLife-App without configuration - Durable, static domestic water meter with integrated radio interface as standard and the option of retrofitting to wired M-Bus
Migration solution as investment protection in the measuring point - sonico® NANO - simultaneous connection to wireless module & drive-by
Wireless module active for stationary reading, while mobile drive-by reading is also possible at the same time.
Applications
- Readout of the sonico® NANO via a fixnet smart metering system (e.g. electricity meter with M-Bus interface)

Downloads
Links
sonico® NANOProperties
- Wired M-Bus according to EN 13757-2/3
- No external power supply or battery required - M-Bus power supply
- In addition to the standard integrated radio interface (Wireless M-Bus 868 MHz according to OMS), the sonico® NANO can be read out simultaneously via wired M-Bus with the NMB-1 module
- In the event of smart metering system failures, the radio interface is still available for billing readings (independence)
- Migration solution as investment protection:
1 step: Automated readout by radio in passing
2 step: Retrofitting with NMB-1 module and migration to a fixed network smart metering system (electricity meter with M-Bus interface) - Pre-programmed primary address for efficient commissioning when connected to electricity meters with M-Bus interface
- M-Bus readout frequency has no influence on the battery life of the sonico® NANO
Product information
General behavior
The NMB-1 sonico® NANO Wired M-Bus Modul supports the following functions:
- Primary address search
- Secondary address search
- Primary address change
- Baud rate change
- Data readout (via secondary and primary addressing)
Technical data
M-Bus data transmission | |
---|---|
Baud rate | 300, 2400 |
Primary address | 1 - 250 programmable (1 pre-programmed) |
Secondary address | sonico® NANO meter number (8 numerical digits) |
M-Bus device load | |
---|---|
Load (incl. power supply) | 5 M-Bus device loads (7.5 mA) |
Connection cable and max. cable length | |
---|---|
M-Bus connection cable | 1.4m (2 x 0.25mm2, polarity-independent) |
M-Bus transmission distance | Network-dependent |
Mass and weight | |
---|---|
Dimensions | 100 x 82 x 28mm |
Weight | ca. 80g |
Operating conditions | |
---|---|
Ambient temperature | -10 to +55°C |
Protection class | IP52 |
Assembly | |
---|---|
By means of tool-free attachment to sonico® NANO |
Information data set | |
---|---|
sonico® NANO with Drive-by configuration | sonico® NANO with fixnet configuration |
Meter number | Meter number |
Manufacturer | Manufacturer |
Version | Version |
Medium | Medium |
Current meter reading | Current meter reading |
Meter reading on the key date (end-of-month value) | - |
Key date | - |
- | Forward volume |
Backflow volume | Backflow volume |
- | Flow rate |
- | Water temperature |
- | Ambient temperature |
Status | Status |
Remaining battery life | Remaining battery life |
Measurement device error | Measurement device error |
Battery alarm | Battery alarm |
Tamper detection | Tamper detection |
Leak detection | Leak detection |
Air detection | Air detection |
Empty pipe detection | Empty pipe detection |
Pipe burst detection | Pipe burst detection |
Backflow detection | Backflow detection |
No usage over an extended period | No usage over an extended period |
Ambient temperature alarm | Ambient temperature alarm |
Water temperature alarm | Water temperature alarm |
Dimension Diagram