M-Bus level converter

PW 3/60 (Discontinued)

PW 3 60 E Pd40204 01

Product categories

M-Bus level converter

System technology

Your benefits

  • Transparent mode of operation:
    Unchanged transfer of read-out data to the communication device
  • Several interference-proof interfaces (RS232 and RS485 for PW 60) for PC communication:
    Greater distances (up to 1000 m via RS485) possible between level converter and PC
  • Operating status display via LED:
    Easy on-site analysis and troubleshooting
  • Clearly marked connection terminals:
    Easy on-site installation

Applications

  • Remote supply and remote reading of M-Bus end devices
PW 3 60 E Pd40204 01

Properties

  • Signal converter from M-Bus to RS232
  • M-Bus level converter for 3 or 60 M-Bus end devices with a standard load of 1,5 mA
  • M-Bus protocol according to EN 13757-3
  • Transfer rates: 300 … 9’600 baud
  • Permanent short-circuit protection
  • Wide power supply range
  • Operating indicator with three (PW 3) or four (PW 60) diodes
  • Additional for PW 60
  • Signal converter from M-Bus to RS485
  • Microcontroller-controlled functions
  • Galvanic separated interfaces
  • Protected against voltage peaks on the M-Bus

Product information

Technical Data
Execution PW 3 PW 60
Current consumption Via external mains adapter Via external mains adapter
Voltage 10,5 … 28 V DC / 10 … 27 V AC 20 … 45 V DC / 20 … 30 V AC
Power consumption 4 W (DC) / 6 W (AC) 15 W (DC/AC)
Housing
Dimensions (HxWxD) 78x56x118 mm 78x70x118 mm
Protection class IP20 IP20
Material ABS plastic ABS plastic
Colour RAL 7035 RAL 7035
Installation Wall- or hat rail TS35 (EN 50022) Wall- or hat rail TS35 (EN 50022)
Weight app. 180 g app. 300 g
Ambient conditions
Operating temperature 0 to +55 °C 0 to +55 °C
Storage temperature -10 to +70 °C -10 to +70 °C
Humidity (non-condensing) 10 to 70% 10 to 70%
Terminals
Terminals
M-Bus (+), (-) PW 3 PW 60 3 terminal pairs for M-Bus end devices 4 terminal pairs for M-Bus end devices
RS232 PW 3 und PW 60 Connection D-Sub-9 (female) or screw terminals (TXD, RXD, GND)
Supply
V+, V- PW 3 Mains adapter 10,5…28 V DC / 10…27 V AC
V+, V- PW 60 Mains adapter 20…45 V DC / 20…30 V AC
M-Bus specifications
Execution PW 3 PW 60
Parameter min. typ. max. min. typ. max.
Max. no. of connectable devices (load unit 1,5 mA each) - - 3 - - 60
Normal operating bus current mA - - 5 - - 90
Display alarm current mA - 35 - 90 - 110
Excessive current switch-off mA 50 - 70 130 - 160
Bus voltage MARK (normal operating current) V 29 30,5 32 36 - 41
Bus voltage SPACE (normal operating current) V - 21 - 24 - 27
Bit threshold end device > centre mA 7 8 9 7 8 9
Collision threshold mA - 35 - - 30 -
Maximum cable length app. km - 11) - - 11) -

1) The maximum possible network reach (entire cable length) as well as the distance to the M-Bus end devices depends greatly on the network topology, the number of connected devices, the cross-section of the used cables and the transfer rate.