Water measurement
sonico® EDGE US
Product categories
Developed for highly precise flow measurement of drinking, industrial and service water.
Water
Hydrology,
Drinking Water
Wastewater
Ultrasonic
Smart Infrastructure
Smart City
Smart Industry
Your benefits
- 4D technology® measures best in class high and low flows (2 inch: Start flow down to 0.02 gpm and up to > 396 gpm).
Immediate detection of leakages and network errors, suitable for fire flow. - Maximum installation flexibility.
Reliable measurements over the full flow range, independent of installation conditions. No straight runs needed even with 90 ° elbows, valves or pumps. - Accuracy by design: 4D technology® maximizes turndown ratio up to R1000.
Highest accuracy across the entire flow profile leads to a cutting edge dynamic range. - Homogeneous 4D-shape measuring pipe with dry sensors and no obstacles or cavities.
Minimal pressure loss enhances high flow capability and minimizes operating costs. Dry sensors lead to increased meter life-time, reliability and dirt resistance.
Applications
- Water measurement, e.g. drinking water or utility water (reservoirs, pumping stations, etc.)
- Suitable for difficult installation conditions such as placement directly before or after 90 ° elbows, valves or pumps
- The time-reverse acoustic principle enables a new level of measuring repeatability unaffected by flow perturbations, electromagnetic or grounding interference and water conductivity
Downloads
Properties
- Minimal pressure loss <0.58 bar
- U0/D0, no need for flow conditioners
- Pressure ratings up to 250 psi
- Bidirectional flow measurement
- Medium temperature up to 32.18 °F to + 122 °F
- Degree of protection IP68
- Ambient temperatures from -4 °F up to 158 °F
- Tamper-proof
- Integrated medium temperature measurement
- Air detection
- External power supply
- Drinking water approval NSF-61 D-HOT
- Approved automatic detection of the direction of flow according to WELMEC 7.2 European Legal Metrology
4D-shape measuring core
Due to the unique 4D-shape pipe design and the implemented 4D technology®, the measurement is independent of the flow profile. Dry sensors guarantee a highly accurate and reliable measurement performance over the entire meter lifetime.
The 4D-shape measuring core allows for installation of the meter directly behind a 90 ° bend or a valve. This flexibility results in minimal installation costs, since no additional on-site work has to be considered.
SONICO® EDGE – in Germany and Switzerland developed and produced. The patented time reverse acoustic principle enables a new level of measuring repeatability unaffected by flow perturbations, electromagnetic or grounding interference and water conductivity.
Ultimate communication
The 4D technology® platform supports a Near Field Communication (NFC) interface that ensure sustained connectivity during the entire product lifetime.
Maximum two of the following available communication module can be attached to the flexible NFC communication interface in parallel:
- Pulse: Pulse output (0.026 gal.; 0.26 gal.; 2.64 gal.; 26.41 gal.; 264.17 gal.) configurable
- Current: 4-20 mA output configurable for uni- or bidirectional measurements.
- ECO E1 or E2: Low Power serial data interface (e.g. to connect a NB-IoT Modem)
- Modbus: Modbus RTU/ASCII protocol with extended flowmeter data
Technical data as acc. to MID/OIML certification
Size | DN | inch | 2 | 3 | 4 | 6 | 8 | 10 | 12 |
---|---|---|---|---|---|---|---|---|---|
Q3 / Q1 | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | ||
Starting flow rate | Qstart | gpm | 0.11 | 0.22 | 0.35 | 0.88 | 1.32 | 1.98 | 2.64 |
Starting flow velocity | V'start | ft/s | 0.02 | 0.01 | 0.01 | 0.02 | 0.01 | 0.02 | 0.02 |
Minimum flow rate ± 5 % | Q1 | gpm | 0.18 | 0.44 | 0.70 | 1.76 | 2.77 | 2.77 | 4.40 |
Minimum flow velocity ± 5 % | V1 | ft/s | 0.03 | 0.03 | 0.03 | 0.03 | 0.03 | 0.03 | 0.03 |
Transitional flow rate ± 2 % | Q2 | gpm | 0.28 | 0.70 | 1.13 | 2.82 | 4.45 | 4.4 | 7.05 |
Transitional flow velocity ± 2 % | V2 | ft/s | 0.04 | 0.04 | 0.04 | 0.05 | 0.04 | 0.04 | 0.04 |
Nominal flow rate ± 2 % | Q3 | gpm | 176.1 | 440.3 | 704.5 | 1761.1 | 2773.8 | 2773.8 | 4402.9 |
Nominal flow velocity ± 2 % | V3 | ft/s | 24.8 | 27.6 | 27.4 | 29.2 | 27.5 | 27.5 | 27.4 |
Overload flow rate | Q4 | gpm | 220.1 | 550.4 | 880.6 | 2201.4 | 3467.3 | 3467.4 | 5503.6 |
Overload flow velocity | V4 | ft/s | 31.1 | 34.5 | 34.3 | 36.5 | 34.3 | 34.3 | 34.3 |
Maximal flow rate | Qmax | gpm | 396.3 | 880.6 | 1320.9 | 2641.7 | 4843.1 | 4843.1 | 8805.7 |
Maximal flow velocity | Vmax | ft/s | 55.9 | 55.2 | 51.4 | 43.9 | 47.9 | 47.9 | 54.8 |
Maximum water temperature | T | °F | 122 | 122 | 122 | 122 | 86 | 86 | 86 |
Nominal pressure | PN | psi | 250 | 250 | 250 | 250 | 250 | 250 | 250 |
4D technology® measuring accuracy
4D technology® offers a bidirectional turndown ratio R1000 and is extremely robust against changes in the flow profile caused by bends, valves or pumps. The patented time-reverse acoustic principle enables a new level of measuring repeatability independent of flow conditions, electromagnetic or grounding interference and medium conductivity.
Typical pressure loss curve
The homogeneous 4D-shape measuring pipe ensures minimal pressure loss (< 0.58 psi on 2" @ Q3), offering highest reliability at lowest operational costs.
Display Information
1. Volume unit indicator (digital) | 8. Main flow direction |
2. Non-billing relevant lines | 9. Battery level symbol |
3. Volume | 10. System alarm icon |
4. Tariff zone 1 | 11. Actual flow direction arrow |
5. Tariff zone 2 | 12. Flow rate |
6. Radio connection status | 13. Flow rate unit indicator (digital) |
7. Test mode information |
Dimensions and weight
Nominal size (mm) | Nominal size (inch) | L (inch) | H (inch) | W (inch) | a (inch) | b (inch) | c1 (inch) | c2 (inch) | Weight (lbs) |
---|---|---|---|---|---|---|---|---|---|
50 | 2 | 7.87 | 8.66 | 65.2 | 5.8 | 4.8 | 5.98 | 6.96 | 28.66 |
65 | 2,5 | 7.87 | 9.29 | 7.28 | 6.02 | 4.8 | 5.98 | 6.96 | 30.87 |
80 | 3 | 7.87 | 9.84 | 7.87 | 6.22 | 6.65 | 5.98 | 6.96 | 35.27 |
100 | 4 | 9.84 | 10.63 | 8.66 | 6.65 | 4.8 | 5.98 | 6.96 | 26.45 |
125 | 6 | 9.84 | 11.22 | 9.84 | 6.65 | 4.8 | 5.98 | 6.96 | 55.12 |
150 | 6 | 11.81 | 13.23 | 11.22 | 7.95 | 4.8 | 5.98 | 6.96 | 72.75 |
200 | 8 | 13.78 | 15.55 | 13.4 | 9.21 | 4.8 | 5.51 | 6.96 | 132.27 |
250 | 10 | 17.72 | 16.73 | 16.14 | 9.49 | 4.8 | 5.98 | 6.96 | 180.78 |
300 | 12 | 19.68 | 18.70 | 18.11 | 9.92 | 4.8 | 5.98 | 6.96 | 253.53 |
Connection | Flanges: EN1 092-1 PN 1 6, others upon request |
Materials
Measuring channel:
- KTL- and powder-coated grey cast iron
Measuring adapter:
- KTL- and powder-coated grey cast iron
IP68 sealing:
- Screwed steel frame with glass and flat seal
Housing:
- ASA Luran plastic
Approvals
CE Design-examination Certificate in conformity with:
- 2014/32/EU (MID) (2019)
- OIML R49:2013 (2019)
- MCERTS Class 1
Drinking water approvals:
- KTW / W270 (2019)
- SVGW
- NSF-61
- WRAS
Power supply
SONICO® EDGE can be powered either mains (with suitable DC adapter) or by an external battery source.
Mains power supply data:
- Input voltage: 24 V DC ± 10 %
- Max. charging current: 250 mA
- The integrated back-up battery (UPS2) ensures autonomous measurements for 24 h if external power supply is interrupted.
1) The external battery source to be provided by the customer. Examples may include eg solar power or wind turbine.
2) UPS – Uninterruptible Power Supply
External battery requirements:
- Input voltage: 9-28 V DC
- Nominal current: 30 mA (24 V)
- Max. peak current: 270 mA
- Battery life time: Depends on battery capacity