Ultrasonic volume measuring meter
Axonic
Categorías de productos
Calefacción / Refrigeración
Ultrasónico
Smart Building
Sus ventajas
- Robust, high grade wear resistant materials:
Excellent measuring stability and reliability - Outstanding metrological properties:
Increased cost effectiveness - Universal applicable with diverse calculators:
Meets various requirements also with regard to interfaces - Integrated intelligence (status and warning messages):
Simple and quick on-site troubleshooting
Aplicaciones
- As a replacement for mechanical impeller heat meters
- Metering of heat and/or cooling consumption in building management
Opciones
- Pulser with 10 m cable
Descargas
Características
- Universal installation position
- Maximum operating pressure PN 16 bar / PN 25 bar
- Temperature up to 130 °C
- Rotatable hinged flanges
- 2D-Barcode with Serial No. and meter details
Conformity according to European Measuring Instruments Directive (MID)- Pulser with 3 m cable
(Standard pulse value: DN 65–100: 10 liters, DN 150: 100 liters) - Environmental class C, Accuracy class 2
Product information
Technical Data
| Execution | AXONIC | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Nominal diameter | DN | mm | 65 | 65 | 80 | 80 | 100 | 100 | 150 | 150 |
| Operating pressure | PN | bar | 16 | 25 | 16 | 25 | 16 | 25 | 16 | 25 |
| Nominal flow rate | qp | m3/h | 25 | 25 | 40 | 40 | 60 | 60 | 150 | 150 |
| Maximum flow rate | qs | m3/h | 50 | 50 | 80 | 80 | 120 | 120 | 300 | 300 |
| Minimum flow rate | qi | m3/h | 0.1 | 0.1 | 0.16 | 0.16 | 0.24 | 0.24 | 0.6 | 0.6 |
| Starting flow | ca. m3/h | 0.04 | 0.04 | 0.08 | 0.08 | 0.1 | 0.1 | 0.3 | 0.3 | |
| Kvs-value | m3/h | 80 | 80 | 110 | 97 | 160 | 160 | 390 | 390 | |
| Temperature range | °C | 1...130 | 1...130 | 1...130 | 1...130 | 1...130 | 1...130 | 1...130 | 1...130 | |
| Measuring range | qi/qp | 1:250 | 1:250 | 1:250 | 1:250 | 1:250 | 1:250 | 1:250 | 1:250 | |
| Dimensions and weights | AXONIC | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Length | L | mm | 200 | 300 | 225 | 300 | 3601) | 360 | 5002) | 500 |
| Height | H | mm | 204 | 204 | 209 | 209 | 219 | 219 | 244 | 244 |
| Height | h | mm | 93 | 93 | 100 | 100 | 111 | 118 | 143 | 150 |
| Flange external dimension | D | mm | 185 | 185 | 200 | 200 | 220 | 235 | 240 | 250 |
| Hole circle diameter | L | mm | 145 | 145 | 160 | 160 | 180 | 190 | 240 | 250 |
| Number of screws | Stk. | 4 | 8 | 8 | 8 | 8 | 8 | 8 | 8 | |
| Weight | ca. kg | 8 | 9 | 9.6 | 10.4 | 14 | 16 | 28 | 31 | |
1) Also supplied in length 250 mm 2) Also supplied in length 300 mm
Dimension Diagram
Materials
Body: Bronze
Installation
| Pipeline: | horizontal | |
| vertical | ||
| Meter head: | upwards | |
| sideways | ||
| downwards |
Typical Head Loss Curve
Installation - Recommendation
A straight inlet or outlet section is not required for AXONIC ultrasonic volume measuring meters. However, an inlet and outlet section of at least 5 x DN is recommendable if sufficient space is available.
Installation recommendations
The choice of installation site must ensure air cannot collect in the meter.
Technical data Pulse generator
| Switching element | ||
|---|---|---|
| Type | Passive Open collector | |
| Switching voltage | Umax | 30 V DC |
| Switching current | Imax | 27 mA |
| Switching capacity | Pmax | 0.81 W |
| Pulse length | 100 ms | |
Pulse value table
| Pulse generator | DN 65...100 1 Pulse = ... Liters | DN 150 1 Pulse = ... Liters |
|---|---|---|
| Pulse | 10 | 100 |
Installation – Recommendations
Pulse transmission interference
In case of interference during the pulse transmission between the pulse
generator and the pulse receiver, (i.e. cable is in the same duct as power cable), we recommend shielded and twisted cables.