The product information is not available in the selected language.
Available languages:

GWFcoder® Wireless M-Bus Radio Module

RCM®

RCM E Pd40232 2 1

Categorías de productos

Agua,
Gas

Wireless M-Bus GWFcoder® Radio Module

Agua

Agua potable

Gas

Cableado

Smart City

Sus ventajas

  • Performance driven design:
    Up to 600 m range depending on environment
  • Real Plug & Play:
    Backward compatible, easy and fast on-site installation with auto interface-detection (no programming required)
  • Use of Wireless M-Bus (OMS®):
    Interoperability with different system partners
  • Custom-tailored RF Mode:
    Up to 15 years battery lifetime

Aplicaciones

  • Simple readout of water and gas meters with GWFcoder® registers without necessity to access buildings
  • Easy and comfortable readout of measuring points with difficult access and within harsh environments
  • «Drive-by» and Fixnetwork (Smart Metering)

Opciones

  • RCM® compact – radio builds one unit with water meter
  • RCM® split – remote installation away from (flooded) water meter
RCM E Pd40232 2 1

Características

  • Battery powered, wireless M-Bus radio module
  • Radio transmission in license free 868 MHz frequency band
  • Water proof design for pit installations (protection class IP68)
  • Transmission of data protocol by wireless M-Bus acc. EN13757-4 (OMS®)
  • Simple installation and automatic start-up after connecting to meter
  • Transmission of latest register value as well as monthly key date value
  • AES128 encrypted wireless protocol
  • For all meter types with GWFcoder® register and SCR(IEC) interface
  • Free route selection – no call-up required
  • Additional information available (e.g. continuous flow, backflow, pipe burst, manipulation) available for MTKcoder® MP
  • Migratable from walk-by/drive-by system to fixed network application
  • approved

Product information

Options
Configuration 1: Walk-by / Drive-by Configuration 2: Fix Network
Data actuality 24 h 15 min (MTKcoder® MP, BGZcoder® / MP / MP AE5) 24 h (MTKcoder® [≤ 2006] / Bulk gas [≤ 2012])
Transmission interval 15 s 1 min
Listening intervall (T2) 5 min 5 min
Warning continuous flow1)
Warning backflow1) (optional)
Warning pipe burst1) (optional)

1)available for MTKcoder® MP

Configurable parameters (by RF or IR)

Configuration interchangable (Drive-by or Fix Network)

Alarm settings On/Off/Reset

Dimension Diagram
RCM E Pd40232 2
Radio-Start behavior

RCM®split: 3 minutes after the connection of the GWFcoder®-meter
RCM®compact: 3 minutes after the flow of 5 liters

Technical Data
Specifications Radio module RCM®
Meter interface SCR(IEC) Protocol 62056-21 / Multiprotocol MP
Frequency band TX: 868,95 MHz (T1) RX: 868,30 MHz (T2)
Transfer protocol Wireless M-Bus acc. EN 13757-4 (OMS®)
Modulation FSK
Radiated power 10 mW
Range Depending on environment (up to 600 m)
Compliance with standard EN 300 220
Approval
Protection class IP68
Cable length Standard 1,4 m
Cable extension max. 25 m
Weight 300 g
Line of sight reading distance (LOS) >1 km
Power supply
Battery 2 x Lithium 3,6 V (not replacable)
Typical battery lifetime 15 years (depending on environment)
Ambient conditions
Operational temperature -15 to +55 °C
Storage temperature -15 to +55 °C
Relative humidity 0 to 100% (submersible)
Information data package Data Example
Manufacturer1) GWF
Radio ID 30124789
Medium1) Water
Version1) 6.0
Meter number1) 13215678
Absolute meter reading1) (daily or 15 min values) 00359,768 m3
Absolute meter reading (key date)1) 00343,417 m3
Date-key date reading 30.04.2013
Remaining battery lifetime Days / Semester
Warnings (available for MTKcoder® MP and support depending on the readout system) Low battery Continuous flow (leakage) Backflow Broken pipe (burst)
Status1) Manipulation

1) This data is read directly from the GWFcoder® register.

Applications
RCM E Pe40232 2ennnnnn