Singlejet meter
UNICOcoder® MP
Categorías de productos
Singlejet consumption meter with M-Bus interface EN 13757-2 for warm water up to 90 °C
Agua
Agua potable
Mecánico
Cableado
M-Bus
Inalámbrico
wM-Bus,
LoRaWAN
Smart Building
Sus ventajas
- Mechanical roller register with 1-litre resolution:
Efficient consumption monitoring in energy data management - Transfer of the effective meter reading:
No data loss and guaranteed security of the billing data - Register without batteries:
No service life restriction - Robust, high grade wear resistant materials:
Excellent measuring stability and reliability - Measurement of low flow rates:
Increased cost effectiveness
Aplicaciones
- Residential consumption monitoring of water consumption within an entire building
- Surface mounting
- Water meter with M-Bus data communication
Opciones
- M-Bus peripheral devices
Descargas
Características
- Singlejet dry-dial meter with magnetic coupling
- 8 dial resolution with 3 comma place
- Register can be turned for best readout position
- Maximum operating pressure PN 16 bar
- Maximum operating temperature 90 °C
- Horizontal or vertical installation
- High grade wear resistant and corrosion proof materials
- Inlet strainer
- Recyclable execution
Conformity according to European Measuring Instruments (MID)- Serial M-Bus-Interface to EN 13757-2 and M-Bus-Protocol EN 13757-3
- Power is provided from the M-Bus central
- Connecting cable, standard length 1,5 m
- UL2043 plenum rating for products installed in air-handling spaces
Product information
GWFcoder®-Technology
The 2nd generation
The well-established GWFcoder®-system reads the absolute mechanical register value precisely and reliably and provides the data through standardized interfaces. The number wheels with three various long, asymmetrically arranged slots are being scanned through light pipes which are connected to five light emitting diodes (LED). Thus, the exact position of each number wheel can be detected and the encoded absolute register read can be transmitted as part of the M-Bus protocol. This functioning principle is patented by GWF. The GWFcoder®-interface provides an incomparably higher level of information compared to meters with pulse output.
GWF enhanced the reliable technology in its 2nd generation, so that 8 instead of 5 number wheels are being scanned and therefore a resolution of 1 liter is possible.
Technical Data
| Execution | ||||||
|---|---|---|---|---|---|---|
| Nominal diameter | DN | mm | 15 | 20 | 20 | 20 |
| Nominal pressure | PN | bar | 16 | 16 | 16 | 16 |
| Connection thread on meter | G...B | Inch | ¾ | 1 | 1 | 1 |
| Connection thread on coupling | R... | Inch | ½ | ¾ | ¾ | ¾ |
| Nominal flow rate | Q3 | m3/h | 2,5 | 2,5 | 2,5 | 4 |
| Maximum flow rate | Q4 | m3/h | 3,125 | 3,125 | 3,125 | 5 |
| Partial limit horizontal ± 3 % | Q2h | l/h | 50 | 50 | 50 | 80 |
| Partial limit vertical ± 3 % | Q2v | l/h | 100 | 100 | 100 | 160 |
| Minimum flow rate horizontal ± 5 % | Q1h | l/h | 31,3 | 31,3 | 31,3 | 50 |
| Minimum flow rate vertical ± 5 % | Q1v | l/h | 62,5 | 62,5 | 62,5 | 100 |
| Kvs-value | m3/h | 3 | 3 | 3 | 5 | |
| Temperature | max. °C | 90 | 90 | 90 | 90 | |
| Measuring range horizontal | R80 | R80 | R80 | R80 | ||
| Measuring range vertical | R40 | R40 | R40 | R40 | ||
Dimension Diagram
| Dimensions and weights | ||||||
|---|---|---|---|---|---|---|
| Length without couplings | A | mm | 110 | 110 | 130 | 130 |
| Length with couplings | mm | 184 | 202 | 222 | 222 | |
| Height | B | mm | 94 | 94 | 94 | 94 |
| Height from pipe centre line | C | mm | 76 | 76 | 76 | 76 |
| Installation depth from pipe centre line | W | mm | 43 | 43 | 43 | 43 |
| Weight without couplings | app. g | 690 | 720 | 770 | 710 | |
| Weight with couplings | app. g | 830 | 950 | 1000 | 940 | |
Installation
| Pipeline: | horizontal | |
| vertical | ||
| Meter head: | upwards | |
| sideways |
Environment and certifications
| Environment | |
|---|---|
| Permissible ambient temperature | +5 to + 55 °C |
| Current consumption | max. 2 M-Bus Loads |
| M-Bus-Interface / -Protocol | EN 13757-2/-3 |
| Standard transmission speed | 2400 baud (optional 300 baud) |
| Register protection class | IP67 |
| Certifications | ||||
|---|---|---|---|---|
| DN 15 | DN 20 | DN 20 | DN 20 | |
| UBA brass | x | x | x | x |
| KTW / W270 | x | x | x | x |
| WRAS (Type: Unico2coder MP) | x | x | x | x |
| NSF-61-G (Type: Unico2coder MP) | - | - | x1) | x1) |
| UL2043 | x | x | x | x |
1) only 1" NPSM execution
| Information | |
|---|---|
| EU-REACH Art. 33 / ChemV Art. 71 | Brass products contain lead > 0,1 % |
Measuring error curve