The product information is not available in the selected language.
Available languages:

Thermal energy meter

Q-Heat 5.5 US

Q Heat 5 5 qp1 5 Left 45 View

Kategorie produktowe

Ciepłomierze / Chłodomierze

The ultrasonic heat meter is one of the flattest devices on the market and, thanks to its removable calculator, can be easily installed even in particularly inaccessible places. The ultrasonic meter can be installed variably as a heat, cold or combination meter. The current consumption, the due date and the due date value can be conveniently recorded with just the push of a button via a display loop.

Ciepłomierze / Chłodomierze

Ultradźwiękowe

Z przewodem

M-Bus

Bezprzewodowe

LoRaWAN

Smart Building

Korzyści

  • Ultrasonic technology:
    Long-term stable energy measurement with highest measurement accuracy
  • Compact design:
    Little installation space required on site
  • Flexible installation:
    - Change of flow and return flow
    - Change of the energy unit
    - Removable calculator (compact/split)
  • Large measuring range:
    up for detection of smallest flow rates
  • User-friendly:
    Parameter setting directly via the device buttons
  • Operational reliability:
    Display of operating faults

Zastosowanie

  • High-end device in the building technology sector
  • Replacement of mechanical impeller heat meters
  • Heat and/or cold consumption measurement in the building technology sector

Opcje

  • Standard Version with M-Bus interface (powered by battery)
  • Retrofittable with external LoRaWAN radio module (RCM-H200 FW-V ≥1.9.18)
Q Heat 5 5 qp1 5 Left 45 View

Cechy

  • Ultrasonic heat and cold meter (combi meter)
  • Nominal diameter DN15 to DN40
  • Nominal flow qp1.5 to qp10
  • Battery life up to 15 years (depending on environment and configuration conditions)
  • Maximum operating pressure PN 16 bar
  • Temperature range 5 – 90 °C
  • Compact design and removable calculator as standard for tight and difficult to access installation situations
  • Any installation position without restrictions, even "overhead"
  • LCD-Resolution 8 digits
  • Display in kWh, MWh, MJ, GJ possible
  • Temperature sensor pt1000
  • Type approval:
    - Heat: Conformity to the European Measuring Instruments Directive (MID)

Product information

Technical data
Ambient conditions
Protection rating Calculator unit: IP65 according to EN 60529 Flow sensor: IP65 according to EN 60529
Transport -25 °C ... 70°C, <95% r.h. (without condensation)
Storage -5°C ... 45°C, <95% r.h. (without condensation)
Operation +5°C ... 55°C, <95% r.h. (without condensation)
Medium Only use water without chemical additives as the medium for this device. Glycol additives or sodium chloride NaCl (common salt) are expressly not permitted!
Standards
Iterference resistance and interference emission EN 301 489-1, EN 301 489-3
Security EN 62368-1 , EN 62479
Quality of the heating medium according to VDI guideline 2035, AGFW standard 510
Influencing quantities
Electromagnetic class E1
Mechanical class M2
Ambient class A
Measuring accuracy class 3/2 (depending on flow sensor)
Calculator unit Temperature range
Temperature rage 1 0°C ... 105°C
Temperature difference range 3K ... 70K
Start of metering temperature difference 0.2K

1 cold register not assessed for conformity. Observe national regulations!

Power supply
Lithium battery Nominal voltage 3.0 V
Lithium content 0.58g
Battery type CR AA
Batteries per device 1 (replaceable)
Battery life Up to 15 years (depending on environment and configuration conditions)
Display-levels
Display 8-digit LCD + pictograms
Energy display (switchable) kWh (default) <-> MWh MJ <-> GJ kWh <-> MJ (only up to 50 liters of cumulative flow) MWh <-> GJ (only up to 50 liters of cumulative flow)
Connecting cable Calculator - volume measuring unit 80 cm
Technical data communication
Connection cable OUT (M-Bus)
Function M-Bus
Length 3 m
Within Scope of delivery included
Protection class IP65
Cable ends End sleeves
Cable sheathing PVC
Connection cable - Colour assignment
M-Bus red black orange (not assigned) brown (not assigned)
M-Bus to RCM-H200 connection red -> brown (ECO+) black -> white (ECO-) orange -> green (ECO Modem) Brown -> (not assigned)
Q heat 5 5 Electrical Schematic 3
Specifications M-Bus
Possible readouts per day 96 (every 15 minutes) 2
Baud rate 300, 2400 (default)

2 if readings are taken less frequently, unused “credits” are stored in the device

Technical data temperature sensor
Temperature sensor
Measuring element Pt1000 according to EN 60751
Type Typ DS
Diameter Ø AGFW - 6.0 mm
Installation variant 3 qp1.5-2.5 qp3.5-10 AGFW 27.5 mm – direct installation Asymmetric 6.0 mm - indirect symmetrical (immersion sleeve)
Cable length Default: 1.5m Optional: 3.0m

3 Observe national and country-specific regulations regarding the use of immersion sleeves

Technical data flow sensor
Flow sensor
Nominal flow qp m3/h 1,5 1,5 2,5 3,5 6 10
Nominal diameter DN mm 15 20 20 25 25 40
Overall length mm 110 130 130 260 260 300
Connection G¾B G1B G1B G1¼B G1¼B G2B
Weight g 530 660 660 1173 1173 1750
Installation location Return or forward flow (switchable up to 50 litres cumulative flow)
Installation position any
Inlet and outlet section not required (no downstream or upstream straight pipe requirement)
Minimum flow qi l/h 15 30 25 28 48 100
Maximum flow qs l/h 3000 3000 5000 7000 12000 20000
Start-up limit q0 l/h 6 10 10 14 24 50
Dynamic range 1:100 1:50 1:100 1:125 1:125 1:100
Accuracy class 2 3 2 2 2 2
Pressure loss at qp mbar 130 65 180 38 122 168
Max. permissible operating pressure bar 16
Min. system pressure to avoid cavitation bar 1,5 1 2 1 1,5 1,5
temperature range °C 5 ... 90
Dimensional drawings
Masszeichnung Q heat 5 5 1
Masszeichnung Q heat 5 5 2
Dimensions
Nominal flow qp m3/h 1,5 1,5 2,5 3,5 6 10
1 Pipe length mm 110 130 130 260 260 300
2 Threads G¾B G1B G1B G1¼B G1¼B G2B
3 Calculator width mm 78
4 Calculator length mm 101,5
5 Total height mm 65 68,48 68,48 84 84 100
6 Height of volume measuring part mm 41,5 45 45 60,5 60,5 76,5

Zapytanie

Last updated: 09.03.2026
Back to the selection