Calculator
CF-55
Categorías de productos
Calefacción / Refrigeración
                                                                                                
                                            Calculator
Calefacción / Refrigeración
Ingeniería de sistemas
Smart Building
Sus ventajas
- Big display: 
 Easy to read
- Universal applicable:
 - Wall-mounted model (Volume measuring meter UNICO® and MTW)
 - Different power supply possibilities
- Option cards for diverse functionalities:
 - Economical basic device
 - Additional functionalities feasible
Aplicaciones
- Metering of heat and/or cooling consumption in building management
- Calculator for local or remote reading
Opciones
- Spezialausführung für kombinierte Wärme-/Kältemessungen (Spezialprogrammierung)
- Option cards for:
 - M-Bus / 2 water meter inputs
 - M-Bus / 2 pulse outputs
 - M-Bus Power / 2 water meter inputs
 - Double M-Bus
 - LonWorks, FTT-10A / 2 water meter inputs (separate supply 24 V AC/DC necessary)
 - Modbus RTU (RS485) / 2 water meters inputs (Power supply module 230 V AC necessary)
 
                                    Descargas
                                                                                                                                                                                                Electrical scheme CF-55
                                                                                                                                                                                                                                                Electrical scheme Axonic CF-55 (german)
                                                                                                                                                                                                                                                Electrical scheme Optiflux CF-55 UD (german)
                                                                                                                                                                                                                                                Electrical scheme Optiflux CF-55 BD (german)
                                                                                                                                                                                                                                                CF-51/55 calculator installation und operating instructions
                                                                                                                                                                                                                                                Option card CF-calculator (German)
                                                                                                                                                                                                                                                Option card M-Bus Power CF-calculator (German)
                                                                                                                                                                                                                                                Option card LONWORKS CF-calculator (German)
                                                                                                                                    
                                                                    Características
- Electronic calculator
- LCD-resolution 7 digits
- Non-volatile memory EEPROM
- Temperature measuring range 0 - 180 °C
- Temperature sensor Pt 100 (2- or 4-wires)
- Standard EN 1434
- 24 month register
- Supply via 12-year battery, mains or M-Bus (pay attention to versions)
- Maximum values with time stamp
- Can be combined with the following volume measuring meters:
 - Mechanical impeller meters with Reed-pulser
 - MID
 Conformity according European Measuring Instruments Directive (MID) Conformity according European Measuring Instruments Directive (MID)
Product information
Dimension Diagram
 
                                                                                
                                                                            Technical Data
| Technical data calculator CF-55 | |
|---|---|
| Temperature measuring range | 0 to 180 °C | 
| Temperature difference | 3 to 160 K | 
| Temperature resolution on display | 0,1 °C | 
| LCD resolution | 7 digits | 
| Max. display resolution | ■ 9’999,999 ■ 999’999,9 ■ 99’999,99 ■ 9’999’999 | 
| Indication device energy | MWh | 
| Indication device volume | m3 | 
| Indication device flow | m3/h | 
| Indication device power | kW | 
| Protection class | IP64 acc. DIN 40050 | 
| Environment class | C acc. EN 1434 | 
| Environment temperature | +5 bis +55 °C (intern installation) | 
| Storage temperature | -10 to +60 °C | 
| EMV | protected acc. DIN EN 50081-1/2, DIN EN 50082-1/2 | 
| Double insulation | Protection class II acc. CEI 60364-4-443 | 
| Power supply | |
|---|---|
| Lithium battery | 2 x 3,6 V-AA (lifetime up to 12 years) | 
| Mains supply | 230 a230 V +10%/-15%, 50 Hz +/-2%, max. 1 VA10%/-15%, 50 Hz +/-2%, max. 1 VA | 
| Supply via M-Bus (option card) | at M-Bus EN 1434-3 max. 2 M-Bus standard loads (2x1,5 mA) | 
| Maximum values | |
|---|---|
| Parameter | Power, flow and inlet temperature (monthly maximum value on display with time stamp) | 
| Period for averaging | 15 min | 
| Internal memory | 24 month maximum values | 
| Inputs from volume measuring meter | |
|---|---|
| Signal | Reed contact, Open collector, Open drain or static contactor | 
| Pulse frequency | max. 128 Hz | 
| Resistore Ron/Roff | ≤150 Ω / ≥ 2 MΩ | 
| Cable diameter | 3.75 +/-0,75 mm | 
| Wire cross-section | 0,2 ... 1,5 mm2 | 
| Option card M-Bus / 2 water meter inputs | |
|---|---|
| M-Bus standard load | 1 standard load= 1,5 mA power consumption | 
| Protocol | M-Bus according EN 1434-3 | 
| Standard transmission rate | 2400 Baud | 
| Pulse input | Characteristics according EN 1434-2 - 7.1.5 class IC | 
| Pulser | Reed contact, Open collector, Open drain or static contactor | 
| Frequency | max. 5 Hz | 
| Pulse length | min. 100 ms | 
| Resistore Ron | max. 10 kΩ | 
| Max. cable length | 10 m | 
| Pulse value | 1 - 250 l/imp. (programmable, standard 10 l) | 
| Option card M-Bus / 2 pulse outputs | |
|---|---|
| Heat energy | Output: Heat energy + volume | 
| Heat and cooling energy | Output: Heat and cooling energy | 
| M-Bus standard load | 1 standard load = 1,5 mA power consumption | 
| Protocol | M-Bus according EN 1434-3 | 
| Standard transmission rate | 2400 Baud | 
| Pulse output | Characteristics according EN 1434-2 - 7.1.3 class OA | 
| Pulser | Galvanically separated optocoupler, bi-polar output | 
| Output frequency | max. 2 Hz | 
| Pulse length | 250 ms +/- 8% | 
| Resistore Ron | max. 20 Ω | 
| Pulse value | According to the smallest digit on the display | 
| Option card M-Bus Power / 2 water meter inputs | |
|---|---|
| M-Bus standard load | 2 standard loads = 3 mA power consumption | 
| Protocol | M-Bus according EN 1434-3 | 
| Standard transmission rate | 2400 Baud | 
| Pulse input | Characteristics according EN 1434-2 - 7.1.5 Klasse IC | 
| Pulser | Reed contact, Open collector, Open drain or static contactor | 
| Frequency | max. 5 Hz | 
| Pulse length | min. 100 ms | 
| Resistore Ron | max. 10 kΩ | 
| Max. cable length | 10 m | 
| Pulse value | 1 - 250 l/imp. (programmable, standard 10 l) | 
| Option card Double M-Bus | |
|---|---|
| M-Bus standard load | 1 standard load = 1,5 mA power consumption | 
| Protocol | M-Bus according EN 1434-3 | 
| Standard transmission rate | 2400 Baud | 
| Option card LonWorks / 2 water meter inputs | |
|---|---|
| Protocol | LonTalk® | 
| Power supply | 24 V AC/DC | 
| Power input | 1 VA | 
| Pulse input | Characteristics according EN 1434-2 - 7.1.5. class IC | 
| Pulser | Reed contact, Open collector, Open drain or static contactor | 
| Frequency | max. 5 Hz | 
| Pulse length | min. 100 ms | 
| Resistore Ron | max. 10 kΩ | 
| Max. cable length | 10 m | 
| Pulse value | 1 - 250 l/Impuls (programmable, standard 10 l) | 
| Temperature sensor | |
|---|---|
| Temperature sensor | Pt 100 (2- or 4-wires) |