sonico® NANO wired M-Bus module
NMB-1
Categorías de productos
Agua
sonico® NANO wired M-Bus module
Agua
Agua potable
Ingeniería de sistemas
Cableado
M-Bus
Software
Infin.io,
GWF Life
Smart City
Smart Building
Sus ventajas
- Wired M-Bus module for tool-free retrofitting of an already installed or new sonico® NANO
Quick and easy installation on site - Pairing between NMB-1 and sonico® NANO takes place automatically via the radio interface
Tap & Go commissioning with GWFLife-App without configuration - Durable, static domestic water meter with integrated radio interface as standard and the option of retrofitting to wired M-Bus
Migration solution as investment protection in the measuring point - sonico® NANO - simultaneous connection to wireless module & drive-by
Wireless module active for stationary reading, while mobile drive-by reading is also possible at the same time.
Aplicaciones
- Readout of the sonico® NANO via a fixnet smart metering system (e.g. electricity meter with M-Bus interface)
Enlaces
sonico® NANOCaracterísticas
- Wired M-Bus according to EN 13757-2/3
- No external power supply or battery required - M-Bus power supply
- In addition to the standard integrated radio interface (Wireless M-Bus 868 MHz according to OMS), the sonico® NANO can be read out simultaneously via wired M-Bus with the NMB-1 module
- In the event of smart metering system failures, the radio interface is still available for billing readings (independence)
- Migration solution as investment protection:
1 step: Automated readout by radio in passing
2 step: Retrofitting with NMB-1 module and migration to a fixed network smart metering system (electricity meter with M-Bus interface) - Pre-programmed primary address for efficient commissioning when connected to electricity meters with M-Bus interface
- M-Bus readout frequency has no influence on the battery life of the sonico® NANO
Product information
General behavior
The NMB-1 sonico® NANO Wired M-Bus Modul supports the following functions:
- Primary address search
- Secondary address search
- Primary address change
- Baud rate change
- Data readout (via secondary and primary addressing)
Technical data
| M-Bus data transmission | |
|---|---|
| Baud rate | 300, 2400 |
| Primary address | 1 - 250 programmable (1 pre-programmed) |
| Secondary address | sonico® NANO meter number (8 numerical digits) |
| M-Bus device load | |
|---|---|
| Load (incl. power supply) | 5 M-Bus device loads (7.5 mA) |
| Connection cable and max. cable length | |
|---|---|
| M-Bus connection cable | 1.4m (2 x 0.25mm2, polarity-independent) |
| M-Bus transmission distance | Network-dependent |
| Mass and weight | |
|---|---|
| Dimensions | 100 x 82 x 28mm |
| Weight | ca. 80g |
| Operating conditions | |
|---|---|
| Ambient temperature | -10 to +55°C |
| Protection class | IP52 |
| Assembly | |
|---|---|
| By means of tool-free attachment to sonico® NANO | |
| Information data set | |
|---|---|
| sonico® NANO with Drive-by configuration | sonico® NANO with fixnet configuration |
| Meter number | Meter number |
| Manufacturer | Manufacturer |
| Version | Version |
| Medium | Medium |
| Current meter reading | Current meter reading |
| Meter reading on the key date (end-of-month value) | - |
| Key date | - |
| - | Forward volume |
| Backflow volume | Backflow volume |
| - | Flow rate |
| - | Water temperature |
| - | Ambient temperature |
| Status | Status |
| Remaining battery life | Remaining battery life |
| Measurement device error | Measurement device error |
| Battery alarm | Battery alarm |
| Tamper detection | Tamper detection |
| Leak detection | Leak detection |
| Air detection | Air detection |
| Empty pipe detection | Empty pipe detection |
| Pipe burst detection | Pipe burst detection |
| Backflow detection | Backflow detection |
| No usage over an extended period | No usage over an extended period |
| Ambient temperature alarm | Ambient temperature alarm |
| Water temperature alarm | Water temperature alarm |
Dimension Diagram