Interface GWFcoder®

CL-SCR

Zaehlerfernauslesung GW Fcoder Interface CL SCR IEC

Kategorie produktowe

Woda,
Ciepłomierze / Chłodomierze,
Gaz

Remote meter reading

Woda

Woda pitna

Ciepłomierze / Chłodomierze

Gaz

Technika systemowa

Smart City

Korzyści

  • Interface converter between GWFcoder® meters and CL/CS communication devices:
    Easy integration into remote meter reading systems
  • Transparent mode of operation:
    Unchanged transfer of read-out data to the communication device
  • Clearly marked connection terminals:
    Easy on-site installation

Zastosowanie

  • The interface is used for the addressed readout of water and gas meters with GWFcoder® registers via a CL interface. Using the interface, it is possible to read out several meters connected in series via a modem.
Zaehlerfernauslesung GW Fcoder Interface CL SCR IEC

Cechy

  • Compatible with CL standard interface IEC 62056-21
  • Two versions available: 1 or 2 channels
  • Depending on the type of modem, up to four meters can be connected to the bus and read out
  • Polarity independent connection of GWFcoder® meter to the interface
  • DIN rail mounting
  • The interface can be used to connect the GWFcoder® meter with SCR(IEC) interface to a communication device with a CL interface. The communication device functions as the master (CL1) and reads out the connected meters (CL0) via the CL interface. The interface is mounted near to the communication device.
    In combination with remote meter readout, it is possible to read out the register readings directly from a control centre. The remote meter readout software must support the GWFcoder® data set.

Product information

Components
E Pe40223 01
Meter connection scheme
Meter type Connecting wires
MTKcoder® IP67 Without approval, Conformity (MID) white, brown
MTKcoder® IP68 Without approval, Conformity (MID) black, red (green cut off)
MTKcoder® MP IP67 Conformity (MID) white, brown
MTKcoder® MP IP68 Conformity (MID) black, red (green cut off)
WPDKcoder WSDKcoder Meitwin with GWFcoder® WPVD with GWFcoder® Without approval black, red (brown cut off)
Meistream mit GWFcoder® Meistream Plus mit GWFcoder® Meitwin with GWFcoder® WPV-MS with GWFcoder® Conformity (MID) white, brown
Meistream with GWFcoder® MP Meistream Plus with GWFcoder® MP Meitwin with GWFcoder® MP WPV-MS with GWFcoder® MP Conformity (MID) black, red (green cut off)
Connection and signal transfer
+/- 20 mA current loop according to IEC 62056-21 Power supply from the active device (Master CL1). After Power «ON», the interface requires app. 60 s before it is ready for operation. After each meter reading, a pause of at least 60 s must be provided. The reading interval of the interface must not be less than 60 s. Voltage drop per GWFcoder® meter ‹ 5 V DC
Ea GWFcoder® register (polarity independent – channel 1)
Eb GWFcoder® register (polarity independent – channel 2)
Interface CL SCRIEC E Pd40223 2
Technical Data
Versions
One-channel – connection for one GWFcoder® meter Two-channel – connection for two GWFcoder® meters
Data transfer
GWFcoder® meter version 5.x 300 baud 7E1 mode A
GWFcoder® meter version 4.x 300 baud 7E2 mode A

The interface functions transparently and does not save data – readout data is transferred to the communication device without being modified.

Installation
The interface should be installed directly at the communication device.
Max. cable length
SCR connection cable 150 m
Type of cable
SCR connection cable U72 (1 x 4 x 0,8)
Dimensions and weight
Dimensions 25 x 78 x 47 mm
Weight app. 50 g
Application area
Temperature -10 to + 60 °C
Protection class IP40
Interfaces
CL standard according to IEC 62056-21
Inductive according to SCR / Protocol IEC 62056-21