Korzyści

  • Revolutionary Multiprotocol interface:
    Investment security due to the interoperability of the meter
  • Transfer of the effective meter reading:
    No data loss and guaranteed security of the billing data
  • No programming required when commissioning the meter in a readout system (Plug & Play):
    Easy and fast on-site installation
  • Measurement of low flow rates:
    Increased cost effectiveness
  • Removable measuring insert:
    Retrofittability and replaceability guaranteed
  • One measuring insert for various bodies:
    Lower storage costs

Zastosowanie

  • Measurement of high flow rates, e.g.
    - Downstream of pumps or at transfer points
    - Reservoir inflows and outflows
  • Measurement of low flow rates during offpeak periods
  • Automated mobile or fixed network readout of relevant billing data
  • Wired or radio remote readout of hard to access metering installations, e.g. meter pits, reservoirs

Opcje

Groswasserzaehler Woltman Verbund Meistream mit GW Fcoder Zaehlwerk

Pliki do pobrania

Cechy

  • Universal installation position
  • No straight flow section required before the meter
  • Register can be turned through 355°
  • Maximum operating pressure PN 16 bar
  • Temperature up to 50 °C
  • Rotor is hydrodynamically, radially, and axially balanced
  • Available in the standard installation lengths for WS and WP meters
  • Powder coating provides optimum corrosion protection
  • Non-ferrous metal design up to PN 16 bar
  • SVGW certification
  • Conformity according to the European Measuring Instrument Directive (MID)
  • Flood-proof register (IP68) with Multiprotocol interface (MP), 5 m cable and provision for a HRI pulser
  • M-Bus standard unit load: 2 unit loads (3 mA)

Product information

Technical Data
Nominal diameter 1) DN mm 40 50 65 65 80 80 100 100 125 150 150 200 250 300
Nominal pressure 2) PN bar 16 16 16 16 16 16 16 16 16 16 16 16 16 16
Nominal flow rate Q3 m3/h 50 50 70 70 120 120 230 230 250 450 450 800 1250 1400
Overload flow rate (few minutes) Q4 m3/h 90 90 120 120 200 200 300 300 350 600 600 1200 1600 2000
Transitional flow rate ±2% Q2 m3/h 0,4 0,4 0,63 0,63 0,51 0,51 0,81 0,81 1,02 1,6 1,6 4,03 6,3 16
Minimum flow rate ±5% Q1 m3/h 0,15 0,15 0,2 0,2 0,2 0,2 0,3 0,3 0,5 0,8 0,8 2 3,5 9
Temperature max.°C 50 50 50 50 50 50 50 50 50 50 50 50 50 50
Dimensions and weights
Overall length L mm 200 2703) 200 300 2254) 300 250 360 250 300 500 350 450 500
Height H mm 157 157 157 157 187 187 187 187 197 214 214 251 275 301
Height h mm 73 73 85 85 95 95 105 105 118 135 135 162 194 226
Dismantling height of measuring unit g mm 237 237 237 237 307 307 307 307 317 393 393 486 511 536
Meter weight app. kg 7,8 9,6 10,1 12 14,2 16,3 18,2 20,2 20,7 35,9 35,9 56,9 79,4 103,8
Measuring unit weight app. kg 1,5 1,5 1,5 1,5 3,2 3,2 3,2 3,2 3,2 5,9 5,9 9,6 9,6 9,6
Body weight app. kg 6,3 8,1 8,6 10,5 11 13,1 15,0 17,0 17,5 30 30 47,3 69,8 94,2

1) Nominal diameter DN 40 upon request
2) High-pressure series PN 40 upon request
3) Also available with 300 mm body length
4) Also available with 200 mm body length

MID certification data
Nominal flow rate Q3 m3/h 40 40 63 63 100 100 160 160 160 400 400 630 630 1000
Temperature max. °C 50 50 50 50 50 50 50 50 50 50 50 50 50 50
Horizontal measuring range R160 R160 R160 R160 R315 R315 R315 R315 R250 R400 R400 R250 R125 R63
Vertical measuring range R100 R100 R100 R100 R125 R125 R160 R160 R125 R200 R200 R250 R100 R63
Standard marking R100 R100 R100 R100 R100 R100 R100 R100 R100 R100 R100 R100 R100 R63
Dimension Diagram
Meistream GW Fcoder MP E Pd10224 2
Materials
Body Cast iron
Measuring unit Plastic
Rotor Plastic
Other materials Brass / non-rusting steel
Measurement error curve
Meistream EN
Typical Head Loss Curve
E Pe10224 loss curve
Installation
Pipeline: horizontal iconHorizontalLine
vertical iconVerticalLine
diagonal iconDiagonal
Meter head: upwards iconArrowToTop
sideways iconArrowLeftRight
Commission
attentionTriangle

When commissioning the meter the measureing section must be filled slowly (bleed slowly).

Dial
Meistream GW Fcoder MP E Pd10224 5
Nominal size DN 50–125 150–300
Smallest reading m3 0,0005 0,005
Maximum register reading m3 1’000’000 10’000’000
Pulse values HRI Pulser
Meter sizes DN 50...125 1 Pulse = ...Liter DN 150...300 1 Pulse = ...Liter
Meistream 100 1000 1000 10000
GWFcoder®-Technology
Mesitream En Coder tech

In the GWFcoder®system, the individual rollers of the mechanical register are read out optoelectronically. The position of the various long asymmetrically arranged slits in the roller counters is scanned using 5 light barriers (lightpipe transmitter and receiver). The light barriers are implemented with phototransistors. LEDs, and light conductors, which are all consecutively scanned and evaluated. The precisely defined position of each individual roller counter is encoded as an absolute roller counter reading and read out as a part of the protocol via the GWFcoder® interface. This functioning principle is patented by GWF. The GWFcoder® interface, compared to a meter with a pulse output, has an incomparably higher level of information content and readout accuracy. A GWFcoder® register does not require a battery, which, in turn, does not compromise existing revision cycles. The readout device supplies the power for the readout.

Moreover, all products with multiprotocol functionality provide the flexibility to switch between wall readout (inductive or CL), Wired M-Bus or radio readout which leads to an easy and fast «Plug & Play» installation on site.

GWFcoder®-Data package
Medium Water
Absolute meter reading 123654 m3
Serial number 43215678
Meter size DN 50

M-Bus: EN 13757 --> Cable colors black / red, polarity independent

ECO: EN 13757-3 --> Cable colors black / green / red, note polarity

Example of use

Wireless read-out 

Meter with GWFcoder® register is read out automatically by radio using a mobile infrastructure (for example radio module RCM® and MEx).