The product information is not available in the selected language.
Available languages:

LoRaWAN™ and wireless M-Bus GWFcoder® MP radio module

RCM®-H200 868 MHz

RCM H200 C0 A0062 freigestellt

Kategorie produktowe

Woda,
Gaz

868 MHz GWFcoder® MP radio module

Woda

Woda pitna

Gaz

Bezprzewodowe

wM-Bus

Smart City

Smart Building

Korzyści

  • 2 communication technologies in one radio module (Dual-mode):
    Investment security and efficient meter reading all the time with fall back to wireless M-Bus if LoRaWAN is not accessible
  • Plug & Play:
    Backward compatible for all meter types with GWFcoder® MP. Easy and fast on-site installation with auto interface-detection (no programming required)
  • Performance driven design:
    Range up to several km (LoRaWAN) and up to 600 m (wireless M-Bus)
  • Integrated monitoring of connectivity and reconnecting mechanisms (LoRaWAN):
    Robust operation with automatic repair options, e. g. due to gateway failures
  • Custom-tailored RF mode:
    Up to 15 years battery lifetime

Zastosowanie

  • Simple readout of water and gas meters with GWFcoder® MP registers without necessity to access buildings
  • Migration of installed meters with GWFcoder® MP registers to a smart metering system via LoRaWAN or wireless M-Bus
  • Energy monitoring, energy reporting and consumption accounting with any cloud solution
  • Integration of water and gas meters with GWFcoder® MP registers in smart city projects

Opcje

  • RCM®-H200 compact (protection class IP67) – radio module builds compact on a water meter
  • Only LoRaWAN or only wireless M-Bus
  • Warnings, all disabled
RCM H200 C0 A0062 freigestellt

Cechy

  • Battery powered radio module with radio transmission in license free 868 MHz frequency band
  • As a split version with cable to the meter:
    Waterproof design for pit installations (protection class IP68)
  • Data transmission in accordance with LoRaWAN (v1.0.4) and wireless M-Bus acc. EN 13757-4 (OMS® Gen. 4, Issue 4.2.1)
  • Transmission of latest register value and further information
  • For all meter types with GWFcoder® MP register and ECO interface
  • Contactless NFC configuration interface
  • Warnings, all enabled:
    Continuous flow / Leak (only medium water), Backflow, Burst Pipe (only if meter size will be configured on site), No Usage over a period of 30 days, Tampering, Connection alarm
  • , UKCA and ICASA approval
  • Migratable (wireless M-Bus):
    From drive-by system to fixed network application

Product information

Dimension Diagram
RCM H200 868 M Hz w M Bus E Pd40265 4
How it works
Radio-Start behaviour
RCM®-H200 split: 3 min after the connection of the GWFcoder® MP meter
RCM®-H200 compact: 3 min after the flow of 5 liters
Technical Data
Specification Radio module RCM®-H200
Meter interface Multiprotocol MP (ECO)
Supported meters Water meter: All with GWFcoder® MP register, sonico® EDGE with ECO E1 or E2 module Gas meter: BGZcoder® MP, BGZcoder® MP AE5 and Ac (requires connection module ACM 5.1.1 ECO) Heat meter: Q-Heat 5.5 US
Frequency band 868 MHz
Radiated power max. 14 dBm (25 mW)
Protection class Split execution: IP68 Compact execution: IP67
Directives : 2014/53/EU / UKCA: Radio Equipment Regulations 2017 No. 1206
Approvals , UKCA and ICASA
Cable length 1 m
Cable extension max. 20 m
Weight 180 g
Specification LoRaWAN
Class A
ADR Yes (gives higher transmission intervals with consistent battery life)
Activation type OTAA
Transfer protocol (payload) GWF specific
Data security AES-128-bit end-to-end encryption over two independent security layers
Range Depending on environment (up to several km)
Real-time clock synchronization Over the LoRaWAN network
Certification LoRa Alliance Certified (v1.0.4)
Specifications Wireless M-Bus
Frequency band Tx: 868,95 MHz
Mode C1
Modulation FSK
Transfer protocol EN 13757-4 (OMS® Gen. 4, Issue 4.2.1)
Range Depending on environment (up to 600 m)
Data security AES128 encrypted wireless protocol, security mode 5 (security profile A) or 7 (security profile B)
Configuration Wireless M-Bus Drive-by Drive-by Privacy Fixnetwork
Data actuality 1 h Monthly key date value 15 min
Transmission interval During day: 20 s During night: 2 min During day: 20 s During night: 2 min 1 min
Power supply
Battery 1 x Lithium 3,0 V (not replacable)
Typical battery lifetime Up to 15 years (depending on environment and configuration conditions)
Ambient conditions
Operational temperature -15 to + 55 °C
Storage temperature -15 to + 65 °C
Relative humidity (only split) 0 to 100 %
Information data package LoRaWAN Data Example MTKcoder® MP
DevEUI RCM®-H200 70B3D538700000AB
Meter manufacturer1) GWF
Medium1) Water
Meter number1) 26215678
Absolute meter reading1) (up to 15 min values) 359,768 m3
Remaining battery life Semester
Warnings Low Battery, LoRaWAN link error, continuous flow / leak, backflow, burst pipe, no usage
Status1) Manipulation

1) This data is read directly from the GWFcoder® MP register

Information data package wireless M-Bus Data Example MTKcoder® MP
Meter manufacturer1) GWF
Radio ID 30124789
Medium1) Water
Version1) 6.0
Meter number1) 26215678
Current absolute meter reading1) Drive-by: Hourly value Fixnetwork: 15 minute value Drive-by Privacy: Will not be transmitted 359,768 m3
Absolute meter reading (key date)1) 343,417 m3
Date-key date reading 01.05.2026
Remaining battery lifetime Days/Semester
Warnings Low battery, continuous flow / leak, backflow, burst pipe, no usage, day or night mode
Status1) Manipulation

1) This data is read directly from the GWFcoder® MP register

Applications
RCM H200 868 M Hz w M Bus E Pe40265 2ene
RCM H200 868 M Hz w M Bus E Pe40265 2en

Zapytanie

Last updated: 29.09.2026
Back to the selection