Contact
en

Woltmanmeter

Meistream with GWFcoder MP

Groswasserzaehler Woltman Verbund Meistream mit GW Fcoder Zaehlwerk 2023 07 31 141042 jono

Product categories

Water

Large water meter with GWFcoder® totalizer MP for cold water up to 50 °C

Water

Drinking Water

Mechanical

Smart City

Your benefits

  • Revolutionary Multiprotocol interface:
    Investment security due to the interoperability of the meter
  • Transfer of the effective meter reading:
    No data loss and guaranteed security of the billing data
  • No programming required when commissioning the meter in a readout system (Plug & Play):
    Easy and fast on-site installation
  • Measurement of low flow rates:
    Increased cost effectiveness
  • Removable measuring insert:
    Retrofittability and replaceability guaranteed
  • One measuring insert for various bodies:
    Lower storage costs

Applications

  • Measurement of high flow rates, e.g.
    - Downstream of pumps or at transfer points
    - Reservoir inflows and outflows
  • Measurement of low flow rates during offpeak periods
  • Automated mobile or fixed network readout of relevant billing data
  • Wired or radio remote readout of hard to access metering installations, e.g. meter pits, reservoirs
  • Measuring of
    - Desalinated / demineralized water
    - Caustic soda up to 20%
    - Saline water up to 10%
    - Chlorinated water up to 1%
    - Glycol-water solutions up to 30%
    - Caustic solutions up to pH value 9

Options

  • High-pressure series up to PN 40 bar
  • High-resolution pulse generator HRI
    Documentation: HRI - EPe10213
  • Radio module RCM® split
    Documentation: RCM® - EPe40232
  • Radio module RCM®-LRW
    Documentation: RCM®-LRW... - EPe40261
Groswasserzaehler Woltman Verbund Meistream mit GW Fcoder Zaehlwerk 2023 07 31 141042 jono

Properties

  • Universal installation position
  • No straight flow section required before the meter
  • Register can be turned through 355°
  • Maximum operating pressure PN 16 bar
  • Temperature up to 50 °C
  • Rotor is hydrodynamically, radially, and axially balanced
  • Available in the standard installation lengths for WS and WP meters
  • Powder coating provides optimum corrosion protection
  • Non-ferrous metal design up to PN 16 bar
  • SVGW certification
  • Conformity according to the European Measuring Instrument Directive (MID)
  • Flood-proof register (IP68) with Multiprotocol interface (MP), 5 m cable and provision for a HRI pulser
  • M-Bus standard unit load: 2 unit loads (3 mA)

Technical Data


Bild Meistream EN

Dimension Diagram


Meistream GW Fcoder MP E Pd10224 2

Materials


Body:Cast iron
Measuring unit:Plastic
Rotor:Plastic
Other materials:Brass / non-rusting steel

Measurement error curve


Meistream EN

Typical Head Loss Curve


Meistream EN errorcurve

Installation


Pipeline: horizontal iconHorizontalLine
vertical iconVerticalLine
diagonal iconDiagonal
Meter head: upwards iconArrowToTop
sideways iconArrowLeftRight

Commission


attentionTriangle

When commissioning the meter the measureing section must be filled slowly (bleed slowly).

Dial


Meistream GW Fcoder MP E Pd10224 5
Nominal size DN 40–125 150–300
Smallest reading m3 0,0005 0,005
Maximum register reading m3 1’000’000 10’000’000

Pulse values HRI Pulser


Meter sizes DN 40...125 1 Pulse = ...Liter DN 150...300 1 Pulse = ...Liter
Meistream 100 1000 1000 10000
Mesitream En Coder tech

GWFcoder®-Technology


In the GWFcoder®system, the individual rollers of the mechanical register are read out optoelectronically. The position of the various long asymmetrically arranged slits in the roller counters is scanned using 5 light barriers (lightpipe transmitter and receiver). The light barriers are implemented with phototransistors. LEDs, and light conductors, which are all consecutively scanned and evaluated. The precisely defined position of each individual roller counter is encoded as an absolute roller counter reading and read out as a part of the protocol via the GWFcoder® interface. This functioning principle is patented by GWF. The GWFcoder® interface, compared to a meter with a pulse output, has an incomparably higher level of information content and readout accuracy. A GWFcoder® register does not require a battery, which, in turn, does not compromise existing revision cycles. The readout device supplies the power for the readout.

Moreover, all products with multiprotocol functionality provide the flexibility to switch between wall readout (inductive or CL), Wired M-Bus or radio readout which leads to an easy and fast «Plug & Play» installation on site.

GWFcoder®-Data package


SCR: IEC 62056-21 Mode A (IEC 1107) --> Cable colors black / red, polarity independent

Medium:Water
Absolute meter reading:123654 m3
Serial number:43215678
Meter size:DN 50

M-Bus: EN 13757 --> Cable colors black / red, polarity independent

ECO: EN 13757-3 --> Cable colors black / green / red, note polarity

Example of use


Wireless read-out 

Meter with GWFcoder® register is read out automatically by radio using a mobile infrastructure (for example radio module RCM® and MEx).

Meistream anwendung EN

Enquire

Last updated: 11.03.2024
Back to the selection