Contact
en
de fr

Multijet meter

MTH

MTH E Pd20313 1

Product categories

Water

Mehrstrahl-Wasserzähler für Heisswasser bis 130°C 

Water

Drinking Water

Mechanical

Smart Building

Your benefits

  • Robust, high grade wear resistant materials:
    Excellent measuring stability and reliability
  • Measurement of low flow rates:
    Increased cost effectiveness

Applications

  • Regular consumption monitoring of water consumption in industrial applications.
  • For nominal flow rates up to 15 m3/h.

Options

  • US Gallon register
  • NPSM threaded connection (only for horizontal housing)
  • Reed pulser IPG14 with 1,5 m or 5 m cable
    Documentation: IPG14 - EPe40217
MTH E Pd20313 1

Properties

  • Multijet impeller wheel, super dry-dial with magnetic coupling
  • Register can be turned for best readout position
  • Maximum operating pressure PN 16
  • Maximum operating temperature 130 °C (can be overloaded to 150 °C for short period of time)
  • Horizontal or vertical (MTH-V…) installation
  • High grade wear resistant and corrosion proof materials
  • Inlet strainer
  • Reconditionable and recyclable execution

Technical Data


Execution MTH (horizontal) MTH-VS or -VF (vertical)1)
Nominal diameter DN mm 15 20 25 25 32 40 50 20 25 32 40
Operating pressure PN bar 16 16 16 16 16 16 16 16 16 16 16
Connection thread on meter G...B Inch ¾ 1 2 2⅜ 1 2
Connection thread on coupling R... Inch ½ ¾ 1 1 2 ¾ 1
Nominal flow rate Qn m3/h 1,5 2,5 3,5 6 6 10 15 2,5 3,5 6 10
Maximum flow rate Qmax m3/h 3 5 7 12 12 20 30 5 7 12 20
Transitional flow rate ±3% Qt l/h 150 200 280 480 480 800 1200 200 280 480 800
Minimum flow rate ±5% Qmin l/h 60 50 70 120 120 200 300 50 70 120 200
Temperature max. °C 130 130 130 130 130 130 130 130 130 130 130
Measuring range Qmin /Qn 1:25 1:50 1:50 1:50 1:50 1:50 1:50 1:50 1:50 1:50 1:50
Dimensions and weights MTH (horizontal) MTH-VS or -VF (vertical)1)
Length without couplings A mm 165 2202) 260 260 260 300 300 105 150 150 200
Length with couplings mm 239 312 352 352 372 432 452 197 242 262 332
Total height w/o Reed pulser B mm 117 123 133 133 133 159 173 - - - -
Total height with Reed pulser B mm 127 133 143 143 143 169 183 - - - -
Meter height from pipe centre line w/o Reed pulser C mm 74 83 90 90 90 113 116 - - - -
Meter height from pipe centre line with Reed pulser C mm 84 93 100 100 100 123 126 - - - -
Meter depth D mm - - - - - - - 148 169 183 226
Meter depth from pipe centre line E mm - - - - - - - 130 143 156 190
Meter width F mm 95 95 100 100 100 135 151 95 98 101 139
Weight without couplings app. kg 1,8 2,1 2,7 2,7 2,8 5,3 5,8 - - - -
Weight without couplings MTH-VS app. kg - - - - - - - 2,0 2,3 2,3 5,8
Weight without couplings MTH-VF app. kg - - - - - - - 2,1 3,5 3,7 7,1
Weight with couplings app. kg 2,1 2,4 3,2 3,2 3,5 6,4 7,4 - - - -
Weight with couplings MTH-VS app. kg - - - - - - - 2,3 2,8 3,0 6,9
Weight with couplings MTH-VF app. kg - - - - - - - 2,4 4,0 4,4 8,2

1)-VS = vertical riser / -VF = vertical down pipe
2)Also supplied in lengths 190 mm

Information
EU-REACH Art. 33 / ChemV Art. 71 Brass products contain lead > 0,1 %

Dimension Diagram w/o Reed pulser


MTH E Pd20313 2

Materials


Housing with screwed connection:UBA Brass (DIN 50930-6)
Sealing plate:UBA Brass (DIN 50930-6)
Impeller / head piece:High grade synthetic material
Bearings:Hard metal, sapphire, Chrome nickel steel
Seal material:EPDM

Measuring error curve


MTH E Pe20313 3 Skizze 1

Typical Head Loss Curve


MTH Vo Me E Pe20311 3

Installation


Pipeline: horizontal iconHorizontalLine
vertical iconVerticalLine
Meter head: upwards iconArrowToTop

Pulse value table


Pulse values (1 Pulse = …Liter) Qn 1,5–6 11) 2,5 10 25 100 250
Pulse values (1 Pulse = …Liter) Qn 10–15 - 2,5 10 25 100 250
Pulse values (1 Pulse = …US Gallons) Qn 1,5–6 11) - 10 - 100 -
Pulse values (1 Pulse = …US Gallons) Qn 10 - - 10 - 100 -

1)Only available in measuring range 1:25

Dimension Diagram with Reed pulser


MTH E Pe20313 3 SIKZZE2

Enquire

Last updated: 11.03.2024
Back to the selection